MaintainX Asset Hub logo
EnterprisePricing
Daikin

Daikin Air Handling Unit OAH004GHAM

Need answers fast?
Explore the manual using AI.

Daikin Air Handling Unit OAH004GHAM
Daikin Air Handling Unit OAH004GHAM

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Air Handling Unit OAH004GHAM

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Air Handling Unit OAH004GHAM

Daikin Air Handling Unit OAH004GHAM

Create an account to install this asset package.

Maintenance Plans for Daikin Air Handling Unit Model OAH004GHAM

Integrate maintenance plans directly into your work orders in MaintainX.

1 Weekly Fan Shaft Bearing Lubrications

Check mark

CAUTION: Bearing overheating potential. Can damage the equipment. Do not over-lubricate bearings. Use only a high grade mineral grease with a 200°F safe operating temperature.

Check mark

Fan Shaft Bearings CAUTION: For safety, stop rotating equipment.

Check mark

Did you add one half of the recommended amount shown in Table 43?

Check mark

Did you start bearing, and run for a few minutes?

Check mark

Did you stop bearing and add the second half of the recommended amount?

Check mark

Did the temperature rise, sometimes 30°F (1°C), after re-lubrication?

Check mark

Enter the operating temperature of the bearing

Check mark

Is the bearing operating at temperature less than 200°F (94°C)?

Check mark

Is the bearing not exceeding 225°F (107°C) for intermittent operation?

Run this procedureArrow right

1 Yearly Coils Cleaning

Check mark

Check the coil for cleanliness

Check mark

If the coil is dirty, proceed with the following steps

Check mark

Brush or vacuum clean the coil

Check mark

Use a chemical coil cleaner on multiple row coils

Check mark

Read and follow the chemical cleaner’s instructions

Check mark

Warning: Some cleaners may contain harsh chemicals

Check mark

Ensure fins are not damaged while cleaning

Check mark

Sign off on the coil cleaning

Run this procedureArrow right

1 Yearly Electrical System Check

Check mark

Annually check and snug all electrical connections

Check mark

Inspect for signs of water damage such as corrosion and repair if necessary

Check mark

Check ground conductor and connection integrity

Check mark

Service if needed;

Run this procedureArrow right

2000 Hourly Supply / Return Fan Motors Lubrication

Check mark

CAUTION: Bearing overheating potential. Can damage the equipment. Do not over-lubricate bearings. Use only a high grade mineral grease with a 200°F safe operating temperature.

Check mark

Motor Bearings: Supply and return fans—Supply and return fan motors should have grease added after every 2000 hours of operation.

Check mark

Using the following procedure, re-lubricate the bearings while the motor is warm, but not running.

Check mark

NOTE: Specific greasing instructions are located on a tag attached to the motor. If special lubrication instructions are on the motor, they supersede all other instructions.

Check mark

Table 43: Recommended Lubricants and Amounts for Fan Motor Bearings

Check mark

Mfr. Grease

Check mark

NEMA Size 56 to 140: Amount to Add (oz.)

Check mark

NEMA Size 140: Amount to Add (oz.)

Check mark

NEMA Size 180: Amount to Add (oz.)

Run this procedureArrow right

48 Hours Air Handling Unit Check

Check mark

Disconnect and lock electrical power source

Check mark

Check tightness of all bearing, wheel, and sheave setscrews (or capscrews). Refer to Table 28 on page 42

Check mark

Recheck belt tension and adjust if necessary. Belts that are tensioned sufficiently to slip one to two seconds at startup perform satisfactorily, extending life and reducing vibration

Check mark

If re-tensioning is necessary, be certain to retain sheave alignment

Run this procedureArrow right

Parts for Daikin Air Handling Unit OAH004GHAM

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Block-Off Plate, Fan Size 355, All kW

910198700

Block-Off Plate, Fan Size 450, All kW

910198701

Block-Off Plate, Fan Size 560, All kW

910311272

Block-Off Plate, Fan Size 630, 5.9 kW; 6.3 kW

910311272

Block-Off Plate, Fan Size 630, 7.1 kW; 9.8 kW

910311273

Block-Off Plate, Fan Size 355, All kW

910198700

Block-Off Plate, Fan Size 450, All kW

910198701

Block-Off Plate, Fan Size 560, All kW

910311272

Block-Off Plate, Fan Size 630, 5.9 kW; 6.3 kW

910311272

Block-Off Plate, Fan Size 630, 7.1 kW; 9.8 kW

910311273

Block-Off Plate, Fan Size 355, All kW

910198700

Block-Off Plate, Fan Size 450, All kW

910198701

Block-Off Plate, Fan Size 560, All kW

910311272

Block-Off Plate, Fan Size 630, 5.9 kW; 6.3 kW

910311272

Block-Off Plate, Fan Size 630, 7.1 kW; 9.8 kW

910311273

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets