Daikin Air Conditioner Indoor Unit FTYN80FXV1
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Power Supply Check
WARNING! Disconnect from main supply before servicing the air conditioner
CAUTION! Don’t touch the metal parts of the indoor unit. It may cause an injury
When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully
When removing or attaching the front panel, support the panel securely with hand to prevent from it falling
For cleansing, do no use hot water above 40°C, benzene, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff
After cleaning, make sure that the front panel is securely fixed
Check the electrical wiring and tighten the wire onto the terminal block if necessary
Sign off on the power supply check
2 Monthly Power Supply Check
WARNING! Disconnect from main supply before servicing the air conditioner
CAUTION! Don’t touch the metal parts of the indoor unit. It may cause an injury
When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully
When removing or attaching the front panel, support the panel securely with hand to prevent from it falling
For cleansing, do no use hot water above 40°C, benzene, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff
After cleaning, make sure that the front panel is securely fixed
Running current for indoor unit
Running voltage for indoor unit
Running current for outdoor unit
Indoor Fan Check
WARNING! Disconnect from main supply before servicing the air conditioner
CAUTION! Don’t touch the metal parts of the indoor unit. It may cause an injury
When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully
When removing or attaching the front panel, support the panel securely with hand to prevent from it falling
For cleansing, do no use hot water above 40°C, benzene, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff
After cleaning, make sure that the front panel is securely fixed
Check if there is any abnormal noise
Sign off on the indoor fan check
3 Monthly Condense Drain Pan & Pipe Check
WARNING: Disconnect from main supply before servicing the air conditioner
CAUTION: Don’t touch the metal parts of the indoor unit. It may cause an injury
When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully
When removing or attaching the front panel, support the panel securely with hand to prevent from it falling
For cleansing, do no use hot water above 40°C, benzene, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff
After cleaning, make sure that the front panel is securely fixed
Check the cleanliness and clean it if necessary
Check the condensate water flow
Sign off on the condense drain pan & pipe check
6 Monthly Compressor Maintenance
WARNING! Disconnect from main supply before servicing the air conditioner
CAUTION! Don’t touch the metal parts of the indoor unit. It may cause an injury
When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully
When removing or attaching the front panel, support the panel securely with hand to prevent from it falling
For cleansing, do no use hot water above 40°C, benzene, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff
After cleaning, make sure that the front panel is securely fixed
Check for refrigerant leak at joint and fitting
Sign off on the compressor maintenance
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX