MaintainX Logo
EnterprisePricing
Daikin

Daikin Air Conditioner FTXS24LVJU

Need answers fast?
Explore the manual using AI.

Daikin Air Conditioner FTXS24LVJU
Daikin Air Conditioner FTXS24LVJU

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Air Conditioner FTXS24LVJU

Daikin Air Conditioner FTXS24LVJU

Create an account to install this asset package.

Maintenance Plans for Daikin Air Conditioner Model FTXS24LVJU

Integrate maintenance plans directly into your work orders in MaintainX.

6 Monthly Titanium Apatite Photocatalytic Air Purifying Filter Cleaning

Check mark

CAUTION!

Check mark

• Before cleaning, be sure to stop the operation and turn the breaker off

Check mark

• Do not touch the aluminum fi ns of the indoor unit. If you touch those parts, this may cause an injury

Check mark

WARNING! For cleaning, do not use the materials as follows

Check mark

• Hot water above 104°F (40°C)

Check mark

• Benzine, gasoline, thinner, other volatile oils

Check mark

• Polishing compound

Check mark

• Scrubbing brushes, other hard stuff

Check mark

Take off the titanium apatite photocatalytic air-purifying filter

Run this procedureArrow right

2 Weekly Air Filter Cleaning

Check mark

CAUTION!

Check mark

• Before cleaning, be sure to stop the operation and turn the breaker off

Check mark

• Do not touch the aluminum fi ns of the indoor unit. If you touch those parts, this may cause an injury

Check mark

WARNING! For cleaning, do not use the materials as follows

Check mark

• Hot water above 104°F (40°C)

Check mark

• Benzine, gasoline, thinner, other volatile oils

Check mark

• Polishing compound

Check mark

• Scrubbing brushes, other hard stuff

Check mark

Pull out the air filters

Run this procedureArrow right

3 Yearly Titanium Apatite Photocatalytic Air Purifying Filter Replacement

Check mark

CAUTION! Before cleaning, be sure to stop the operation and turn the breaker off. Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury.

Check mark

WARNING! For cleaning, do not use hot water above 104°F (40°C), Benzine, gasoline, thinner, other volatile oils, Polishing compound, Scrubbing brushes, other hard stuff.

Check mark

Turned the breaker off?

Check mark

Avoided touching the aluminum fins of the indoor unit?

Check mark

Avoided using prohibited cleaning materials?

Check mark

Take off the titanium apatite photocatalytic air-purifying filter.

Check mark

Opened the front panel and pulled out the air filters?

Check mark

Held the recessed parts of the frame and unhooked the 4 claws?

Check mark

Removed the tabs on the filter frame and replaced with a new filter?

Run this procedureArrow right

Air Conditoiner Check

Check mark

Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded

Check mark

Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit

Check mark

Check that the drain comes smoothly out of the drain hose during COOL or DRY operation

Check mark

NOTE! If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the service shop if this is the case

Check mark

Sign off on the air conditioner check

Run this procedureArrow right

Front Panel Cleaning

Check mark

CAUTION!

Check mark

• Before cleaning, be sure to stop the operation and turn the breaker off

Check mark

• Do not touch the aluminum fi ns of the indoor unit. If you touch those parts, this may cause an injury

Check mark

WARNING! For cleaning, do not use the materials as follows

Check mark

• Hot water above 104°F (40°C)

Check mark

• Benzine, gasoline, thinner, other volatile oils

Check mark

• Polishing compound

Check mark

• Scrubbing brushes, other hard stuff

Check mark

Remove the front panel

Run this procedureArrow right

Parts for Daikin Air Conditioner FTXS24LVJU

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Titanium Apatite Photocatalytic Air Purifying Filter

KAF970A46

Titanium Apatite Photocatalytic Air Purifying Filter

KAF970A46

Titanium Apatite Photocatalytic Air Purifying Filter

KAF970A46

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets