Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more
Daikin Air Conditioner FTX50GV1B
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
2 Weekly Air Filter Cleaning
CAUTION! Before cleaning, be sure to stop the operation and turn off the circuit breaker
Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury
When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully
When removing or attaching the front panel, support the panel securely with hand to prevent it from falling
For cleaning, do not use hot water above 40°C, benzine, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff
After cleaning, make sure that the front panel is securely fixed
Wash the air filters with water or clean them with vacuum cleaner
If the dust does not come off easily, wash them with neutral detergent thinned with lukewarm water, then dry them up in the shade
NOTE! Operation with dirty filters – cannot deodorize the air – cannot clean the air – results in poor heating or cooling – may cause odor
6 Monthly Titanium Apatite Photocatalytic Air Purifying Filter Cleaning
CAUTION! Before cleaning, be sure to stop the operation and turn off the circuit breaker
Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury
When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully
When removing or attaching the front panel, support the panel securely with hand to prevent it from falling
For cleaning, do not use hot water above 40°C, benzine, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff
After cleaning, make sure that the front panel is securely fixed
Remove dust with a vacuum cleaner and wash lightly with water
If it is very dirty, soak it for 10 to 15 minutes in water mixed with a neutral cleaning agent
After washing, shake off remaining water and dry in the shade
Front Panel Cleaning
CAUTION!
Before cleaning, be sure to stop the operation and turn off the circuit breaker
Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury
When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully
When removing or attaching the front panel, support the panel securely with hand to prevent it from falling
For cleaning, do not use hot water above 40°C, benzine, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff
After cleaning, make sure that the front panel is securely fixed
Open the front panel. Hold the panel by the tabs on the two sides and lift it until it stops with a click
Remove the front panel. Open the front panel further while sliding it to either the left or right and pulling it toward you. This will disconnect the rotation dowel on one side. Then disconnect the rotation dowel on the other side in the same manner
Indoor Unit, Outdoor Unit and Remote Controller Cleaning
CAUTION!
Before cleaning, be sure to stop the operation and turn off the circuit breaker
Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury
When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully
When removing or attaching the front panel, support the panel securely with hand to prevent it from falling
For cleaning, do not use hot water above 40°C, benzine, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff
After cleaning, make sure that the front panel is securely fixed
Did you stop the operation and turn off the circuit breaker before cleaning?
Did you avoid touching the aluminum fins of the indoor unit?
3 Yearly Titanium Apatite Photocatalytic Air Purifying Filter Replacement
CAUTION! Before cleaning, be sure to stop the operation and turn off the circuit breaker
Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury
WARNING! For cleaning, do not use any of the following: Water hotter than 104°F (40°C), Volatile liquid such as benzine, gasoline and thinner, Polishing compounds, Rough materials such as a scrubbing brush, Sprays such as deodorizers
Remove the tabs on the filter frame and replace with a new filter
Dispose of the old filter as non-flammable waste
NOTE! Operation with dirty filters – cannot deodorize the air – cannot clean the air – results in poor heating or cooling – may cause odor
Dispose of old filters as non-flammable waste
To order a titanium apatite photocatalytic air-purifying filter, contact the dealer where you bought the air conditioner
Sign off on the filter replacement
Access the parts list for your equipment in MaintainX.
Titanium Apatite Photocatalytic Air-Purifying Filter without Frame
KAF952B42
Titanium Apatite Photocatalytic Air-Purifying Filter without Frame
KAF952B42
Titanium Apatite Photocatalytic Air-Purifying Filter without Frame
KAF952B42
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX