The Daikin Air Conditioner FTKS50LVMA/RKS50LVMA is a high-efficiency cooling solution designed for residential and commercial applications. Known for its reliability and advanced technology, this model ensures optimal comfort and energy savings, making it a preferred choice for climate control.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Air Conditioner FTKS50LVMA/RKS50LVMA

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Air Conditioner FTKS50LVMA/RKS50LVMA

Daikin Air Conditioner FTKS50LVMA/RKS50LVMA

Create an account to install this asset package.

Maintenance Plans for Daikin Air Conditioner Model FTKS50LVMA/RKS50LVMA

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Battery Replacement

Check mark

Warning: Always replace batteries with the same type and replace both old batteries together

Check mark

Batteries replaced?

Check mark

Type of batteries used

Check mark

If the system is not used for a long time, take the batteries out

Check mark

The batteries will last for approx. 1 year. If the remote controller display begins to fade and the degradation of reception performance occurs within a year, replace both 2 batteries

Check mark

Are the attached batteries provided for the initial use of the system?

Check mark

The usable period of the batteries may be short depending on the manufactured date of the air conditioner

Check mark

Sign off on the battery replacement

Run this procedureArrow right

6 Monthly Air-Purifying Filter Maintenance

Check mark

Warning: The method of cleaning and replacement of the filters may differ depending on the model. Refer to the label attached to the separately sold filters themselves.

Check mark

Open the front panel and pull out the air filters

Check mark

Hold the recessed parts of the frame and unhook the 4 claws

Check mark

Take off the titanium apatite photocatalytic air-purifying filter

Check mark

Vacuum dusts, and soak in lukewarm water or water for about 10 to 15 minutes if dirt is heavy

Check mark

Do not remove the filter from frame when washing with water

Check mark

After washing, shake off remaining water and dry in the shade

Check mark

Since the material is made out of polyester, do not wring out the filter when removing water from it

Check mark

Remove the tabs on the filter frame and replace with a new filter

Run this procedureArrow right

Air Conditioner Check

Check mark

Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded

Check mark

Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit

Check mark

Check that the drain comes smoothly out of the drain hose during COOL or DRY operation

Check mark

If no drain water is seen, is water leaking from the indoor unit?

Check mark

Before a long idle period

Check mark

Operate the FAN only for several hours on a nice day to dry out the inside

Check mark

After operation stops, turn off the breaker for the room air conditioner

Check mark

Clean the air filters and set them again

Check mark

Take out batteries from the remote controller

Run this procedureArrow right

Air Conditioner Cleaning

Check mark

CAUTION: Before cleaning, be sure to stop the operation and turn off the circuit breaker

Check mark

Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury

Check mark

Is the operation stopped and circuit breaker turned off?

Check mark

Clean Indoor unit

Check mark

Clean Outdoor unit

Check mark

Clean Remote controller

Check mark

For cleaning, do not use the materials as follows: Hot water above 40°C, Benzine, gasoline, thinner, other volatile oils, Polishing compound, Scrubbing brushes, other hard stuff

Check mark

Sign off on the air conditioner cleaning

Run this procedureArrow right

Front Panel Cleaning

Check mark

CAUTION: When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully

Check mark

CAUTION: When removing or attaching the front panel, support the panel securely with hand to prevent it from falling

Check mark

CAUTION: After cleaning, make sure that the front panel is securely fixed

Check mark

Is the front panel bothered by dirt?

Check mark

If the front panel is dirty, proceed with the following steps

Check mark

Remove the front panel

Check mark

Did you open the front panel?

Check mark

Did you slide the front panel to either the left or right and pull it toward you?

Check mark

Did you disconnect the front panel shaft on the other side in the same manner?

Run this procedureArrow right

Parts for Daikin Air Conditioner FTKS50LVMA/RKS50LVMA

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Air-Purifying Filter

KAF970A46

Cooling Pump

ARC452A13

Dry Batteries

AAA.LR03

Heat Pump

ARC452A4

Air-Purifying Filter

KAF970A46

Cooling Pump

ARC452A13

Dry Batteries

AAA.LR03

Heat Pump

ARC452A4

Air-Purifying Filter

KAF970A46

Cooling Pump

ARC452A13

Dry Batteries

AAA.LR03

Heat Pump

ARC452A4

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets