Crown Boiler FW-6
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Heating Plant Inspection
Periodic observation of the Heating Plant is advised to insure safe efficient operation.
Check control operation and settings.
Check for odors or soot deposit marks. Door seal may need adjusting or vent connections may require additional sealing.
Observe burner operation for excessive noise or vibration.
Check for water leaks.
Sign off on the heating plant inspection
6 Monthly Boiler Cleaning
- Boilers which operate only for heating, need only be cleaned at the end of each heating season. Boilers which operate year round should be cleaned Bi-annually.
It is important that the boiler be cleaned immediately after shut-down and while the cast iron is still warm, firstly because the deposits are more readily removed and, secondly, hardened deposits will absorb moisture and will cause corrosion.
- Before starting to clean the boiler: shut off all power to burner and boiler.
Shut off the fuel supply to burner in accordance with Burner Manufacturer's Instruction Manual.
To clean boiler:
1). Remove smoke pipe and flue collector at back of boiler.
2). Disconnect burner fuel lines as needed to open front door.
3). Remove all flue baffles.
4). Using the cleaning brush, scrub all fireside surfaces in combustion chamber, flue passages and flue collector area.
Access the parts list for your equipment in MaintainX.
HI-LIMIT
L4008A
HI-LIMIT
L4008A
HI-LIMIT
L4008A
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX