MaintainX Asset Hub logo
EnterprisePricing
Carrier

Carrier Packaged and Dedicated Outdoor Air Units 50TC

Need answers fast?
Explore the manual using AI.

Carrier Packaged and Dedicated Outdoor Air Units 50TC
Carrier Packaged and Dedicated Outdoor Air Units 50TC

Carrier's Packaged and Dedicated Outdoor Air Units 50TC provide efficient climate control solutions for commercial applications. These units are designed for optimal performance and reliability, ensuring consistent air quality and comfort in various environments. Ideal for both new installations and replacements, they offer advanced features tailored to meet diverse HVAC needs.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Carrier Packaged and Dedicated Outdoor Air Units 50TC

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Carrier Packaged and Dedicated Outdoor Air Units 50TC

Carrier Packaged and Dedicated Outdoor Air Units 50TC

Create an account to install this asset package.

Maintenance Plans for Carrier Packaged and Dedicated Outdoor Air Units Model 50TC

Integrate maintenance plans directly into your work orders in MaintainX.

3 Monthly Inspection

Check mark

Return air filter replacement

Check mark

Outdoor hood inlet filters cleaned

Check mark

Belt tension checked

Check mark

Belt condition checked

Check mark

Pulley alignment checked

Check mark

Fan shaft bearing locking collar tightness checked

Check mark

Condenser coil cleanliness checked

Check mark

Condensate drain checked

Check mark

Sign off on the 3 Monthly Inspection

Run this procedureArrow right

Adjusting the Condenser-Fan

Check mark

Shut off the unit power supply and apply the appropriate lockout/tagout procedures

Check mark

Remove the condenser-fan assembly (grille, motor, and fan)

Check mark

Loosen the fan hub setscrews

Check mark

Upload a photo of the adjusted fan height as shown in Fig. 32

Check mark

Tighten the setscrews

Check mark

Replace the condenser-fan assembly

Check mark

Sign off on the condenser-fan adjustment

Run this procedureArrow right

Belt Tension Maintenance

Check mark

Loosen the four motor mounting nuts that attach the motor to the blower rail

Check mark

Loosen the two jack bolt locking nuts beneath the motor mounting plate. Turn the jack bolt locking nut counterclockwise to loosen

Check mark

Turn the jack bolts counterclockwise to loosen and clockwise to tighten

Check mark

Adjust the V-belt for proper tension

Check mark

Make sure the fan shaft and motor shaft are parallel before tightening the motor mount nuts

Check mark

Make adjustments as necessary

Check mark

Tighten the four motor mounting nuts

Check mark

Check the V-belt tension. Make adjustments as necessary

Check mark

Re-tighten the four motor mounting nuts

Run this procedureArrow right

Changing Fan Speed

Check mark

Shut off the main unit power supply, and use the approved lockout/tag-out procedures.

Check mark

Loosen the belt by loosening the motor adjustment bolts as described in the Belt Adjustment section.

Check mark

Loosen the movable pulley flange setscrew.

Check mark

Adjust the movable flange

Check mark

Warning: Increasing fan speed increases load on the motor. Do not exceed maximum speed specified in the Product Data or motor amperage listed on the unit rating plate.

Check mark

Set the movable flange at the nearest keyway or flat of the pulley hub and tighten the setscrew to torque of 72 ± 5 in.-lb (8.14 ± 0.56 Nm).

Check mark

Sign off on the fan speed change

Run this procedureArrow right

Compressor Replacement

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

Connect service gages to suction and discharge pressure fittings

Check mark

Energize the compressor

Check mark

Check if suction pressure drops and discharge pressure rises

Check mark

If the suction pressure does not drop and the discharge pressure does not rise to normal levels:

Check mark

Check if the evaporator fan is rotating in the wrong direction

Check mark

Turn off power to the unit. Use applicable lockout/tag-out procedures

Check mark

Reverse any two of the unit power leads

Check mark

Reapply power to the compressor

Run this procedureArrow right

Parts for Carrier Packaged and Dedicated Outdoor Air Units 50TC

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Accessory Aspirator Box

33ZCASPCO2

Accessory Co2 Sensor

33ZCSENCO2

CO2 for DCV Control using a Duct-Mounted CO2 Sensor

CRCBDIOX005A00

Coil Cleaner

P902-0305

Coil Cleaner

P902-0301

Accessory Aspirator Box

33ZCASPCO2

Accessory Co2 Sensor

33ZCSENCO2

CO2 for DCV Control using a Duct-Mounted CO2 Sensor

CRCBDIOX005A00

Coil Cleaner

P902-0305

Coil Cleaner

P902-0301

Accessory Aspirator Box

33ZCASPCO2

Accessory Co2 Sensor

33ZCSENCO2

CO2 for DCV Control using a Duct-Mounted CO2 Sensor

CRCBDIOX005A00

Coil Cleaner

P902-0305

Coil Cleaner

P902-0301

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Carrier

Explore Other Assets