Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Busch Vacuum Pump MM 1252 A VF
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
5000 Hourly/2 Yearly Vacuum Pump Sealing Ring Replacement
Safety Precautions
Ensure electrical installation work is executed by qualified personnel.
Wear appropriate personal protective equipment if the machine is contaminated with hazardous material.
Allow the machine to cool down before touching it to avoid burns.
Allow the machine to cool down before draining liquids to avoid burns.
Avoid direct contact with the flow of gases and/or liquids when draining condensate or venting the machine.
Ensure maintenance work is executed by qualified personnel and respect maintenance intervals.
Do not use incompatible solvents to clean the machine to avoid removing safety stickers and protective paint.
Preparation
6 Monthly Vacuum Pump Maintenance
Safety Precautions
Ensure all electrical work is executed by qualified personnel.
Wear appropriate personal protective equipment if the machine is contaminated with hazardous material.
Allow the machine to cool down before touching it to avoid burns.
Allow the machine to cool down before draining liquids to avoid burns.
Avoid direct contact with discharged gases and/or liquids to prevent burns.
Ensure maintenance work is executed by qualified personnel.
Preparation
Stop the machine and lock it to prevent accidental start-up.
3 Monthly Vacuum Pump Oil Level Check
Safety Precautions
Ensure all electrical installation work is executed by qualified personnel.
Wear appropriate personal protective equipment if the machine is contaminated with hazardous material.
Ensure the machine has cooled down before touching it.
Ensure the machine has cooled down before draining liquids.
Avoid direct contact with the flow of gases and/or liquids when draining condensate.
Ensure maintenance work is executed by qualified personnel.
Do not use incompatible solvents to clean the machine.
Preparation
20000 Hourly Vacuum Pump Oil Change
Safety Precautions
Ensure electrical installation work is executed by qualified personnel.
Wear appropriate personal protective equipment if the machine is contaminated with hazardous material.
Allow the machine to cool down before touching it to avoid burns.
Allow the machine to cool down before draining liquids to avoid burns.
Avoid direct contact with discharged gases and/or liquids to prevent burns.
Ensure maintenance work is executed by qualified personnel.
Do not use incompatible solvents to clean the machine.
Preparation
10000 Hourly/2 Yearly Vacuum Pump Pressure Relief Lines Check
Safety Precautions
Ensure electrical installation work is executed by qualified personnel.
Wear appropriate personal protective equipment if the machine is contaminated with hazardous material.
Allow the machine to cool down before touching it to avoid burns.
Allow the machine to cool down before draining liquids to avoid burns.
Avoid direct contact with the flow of gases and/or liquids when draining condensate or venting the machine.
Ensure maintenance work is executed by qualified personnel and respect maintenance intervals.
Avoid using incompatible solvents to clean the machine.
Preparation
Access the parts list for your equipment in MaintainX.
Service Kit
0992 214 853
Inlet Screen (Is)
0534 000 041
Inlet Flange Lower Part, Includes Non-Return Valve (Nrv)
0916 000 670
Inlet Flange Lower Part, Light Chemical Version, Includes Non-Return Valve (Nrv)
0916 532 372
Oil Vs 150, 1L Packaging
0831 164 883
Service Kit
0992 214 853
Inlet Screen (Is)
0534 000 041
Inlet Flange Lower Part, Includes Non-Return Valve (Nrv)
0916 000 670
Inlet Flange Lower Part, Light Chemical Version, Includes Non-Return Valve (Nrv)
0916 532 372
Oil Vs 150, 1L Packaging
0831 164 883
Service Kit
0992 214 853
Inlet Screen (Is)
0534 000 041
Inlet Flange Lower Part, Includes Non-Return Valve (Nrv)
0916 000 670
Inlet Flange Lower Part, Light Chemical Version, Includes Non-Return Valve (Nrv)
0916 532 372
Oil Vs 150, 1L Packaging
0831 164 883
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX