The Atlas Copco Stationary Air Compressor GX7 is a reliable and efficient air compressor designed for industrial applications. With its robust construction and advanced technology, the GX7 ensures optimal performance and longevity, making it an ideal choice for various compressed air needs.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Atlas Copco Stationary Air Compressor GX7
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly / 1000 Hourly Oil Filter and Oil Separator Replacement
ATTENTION: Never mix oil of different brands or types.
Run the compressor until warm. Stop the compressor, close the air outlet valve, switch off the voltage and depressurize by unscrewing filler plug one turn to permit any pressure in the system to escape. Depressurize the air receiver by opening drain valve.
Drain the oil by opening drain valve. Close the valve after draining. Deliver the oil to the local oil collection service.
Remove oil filter and separator. Clean the seats on the manifold. Oil the gaskets of the new filter and separator and screw them into place. Tighten firmly by hand.
Fill oil separator/tank with oil until the level reaches the middle of sight-glass. Take care that no dirt drops into the system. Fit and tighten plug. Close drain valve of the air receiver.
Run the compressor for a few minutes. Stop the compressor and wait a few minutes to allow the oil to settle. Depressurize the system by unscrewing filler plug one turn to permit any pressure in the system to escape. Depressurize the air receiver by opening drain valve.
Fill the separator/ tank with oil until the sight-glass is 3/4 full. Tighten plug and close drain valve of the air receiver.
Sign off on the oil filter and oil separator replacement
1 Yearly / 2000 Hourly Air Filter Replacement
Inspect air filter
Compressor stopped, air outlet valve closed and voltage switched off?
Remove the filter cover and the filter element
Discard the air filter element
Fit the new element and the cover
Sign off on the air filter replacement
1 Yearly / 2000 Hourly Oil Filter and Oil Separator Replacement
Warning: Ensure the compressor is warm before starting the procedure.
Compressor run until warm?
Compressor stopped, air outlet valve closed, voltage switched off, and system depressurized?
Oil drained by opening drain valve?
Deliver the oil to the local oil collection service.
Oil filter and separator removed and seats on the manifold cleaned?
Gaskets of the new filter and separator oiled and screwed into place?
Fill oil separator/tank with oil until the level reaches the middle of sight-glass.
No dirt dropped into the system?
1 Yearly / 4000 Hourly Oil Replacement
Is Atlas Copco Roto-Inject fluid used?
Run the compressor until warm. Stop the compressor, close the air outlet valve, switch off the voltage and depressurize by unscrewing filler plug one turn to permit any pressure in the system to escape. Depressurize the air receiver by opening drain valve.
Drain the oil by opening drain valve. Close the valve after draining. Deliver the oil to the local oil collection service.
Remove oil filter and separator. Clean the seats on the manifold. Oil the gaskets of the new filter and separator and screw them into place. Tighten firmly by hand.
Fill oil separator/tank with oil until the level reaches the middle of sight-glass. Take care that no dirt drops into the system. Fit and tighten plug. Close drain valve of the air receiver.
Run the compressor for a few minutes. Stop the compressor and wait a few minutes to allow the oil to settle. Depressurize the system by unscrewing filler plug one turn to permit any pressure in the system to escape. Depressurize the air receiver by opening drain valve. Fill the separator/ tank with oil until the sight-glass is 3/4 full. Tighten plug and close drain valve of the air receiver.
Is Atlas Copco Roto-Inject fluid used?
If not, mineral oil can be used after taking following precautions: the previously used oil should first be drained and the system flushed the oil filter and oil separator should be replaced
Does the oil meet the requirements as specified below?
1 Yearly / 500 Hourly Oil Filter and Oil Replacement
ATTENTION: Never mix oil of different brands or types.
Run the compressor until warm. Stop the compressor, close the air outlet valve, switch off the voltage and depressurize by unscrewing filler plug one turn to permit any pressure in the system to escape. Depressurize the air receiver by opening drain valve.
Drain the oil by opening drain valve. Close the valve after draining. Deliver the oil to the local oil collection service.
Remove oil filter and separator. Clean the seats on the manifold. Oil the gaskets of the new filter and separator and screw them into place. Tighten firmly by hand.
Fill oil separator/tank with oil until the level reaches the middle of sight-glass. Take care that no dirt drops into the system. Fit and tighten plug. Close drain valve of the air receiver.
Run the compressor for a few minutes. Stop the compressor and wait a few minutes to allow the oil to settle. Depressurize the system by unscrewing filler plug one turn to permit any pressure in the system to escape. Depressurize the air receiver by opening drain valve. Fill the separator/ tank with oil until the sight-glass is 3/4 full. Tighten plug and close drain valve of the air receiver.
Sign off on the oil filter and oil replacement
Access the parts list for your equipment in MaintainX.
Air Filter Kit
1613 9001 00
Belt Set
1613 9032 02
Belt Set
1613 9032 04
DD Kit
2901 0526 00
Filter Kit
2901 0852 00
Air Filter Kit
1613 9001 00
Belt Set
1613 9032 02
Belt Set
1613 9032 04
DD Kit
2901 0526 00
Filter Kit
2901 0852 00
Air Filter Kit
1613 9001 00
Belt Set
1613 9032 02
Belt Set
1613 9032 04
DD Kit
2901 0526 00
Filter Kit
2901 0852 00
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX