Atlas Copco Oil-Injected Rotary Screw Compressor GA30VSD+

The Atlas Copco Oil-Injected Rotary Screw Compressor GA30VSD+ is a high-efficiency compressor designed for industrial applications. With its variable speed drive technology, it optimizes energy consumption while delivering reliable compressed air performance, making it an ideal choice for various operational needs.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Atlas Copco Oil-Injected Rotary Screw Compressor GA30VSD+

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Atlas Copco Oil-Injected Rotary Screw Compressor GA30VSD+

Atlas Copco Oil-Injected Rotary Screw Compressor GA30VSD+

Create an account to install this asset package.

Maintenance Plans for Atlas Copco Oil-Injected Rotary Screw Compressor Model GA30VSD+

Integrate maintenance plans directly into your work orders in MaintainX.

1 Daily Oil-Injected Rotary Screw Compressor Check

Check mark

Check oil level. If needed, top up the oil

Check mark

Check readings on display

Check mark

Check that condensate is discharged during operation

Check mark

Drain condensate

Run this procedureArrow right

1 Monthly Condenser Cleaning

Check mark

Compressor stopped, air outlet valve closed and voltage switched off

Check mark

Dirt on the condenser inlet removed with a vacuum cleaner

Check mark

Cleaned with an air jet in the reverse direction to normal flow using low pressure air

Check mark

Compressed air nozzle kept more than 30 cm away from the condenser

Check mark

Dust from inside the dryer removed, e.g. with a vacuum cleaner

Check mark

Water or solvents not used to clean the condenser

Check mark

Sign off on the condenser cleaning

Run this procedureArrow right

3 Monthly Oil-Injected Rotary Screw Compressor Check

Check mark

Check coolers, clean if necessary

Check mark

Remove the air filter element and inspect. Replace damaged or heavily contaminated elements

Check mark

Check the filter elements of the electric cabinet. Replace if necessary

Run this procedureArrow right

4000 Hourly / 1 Yearly Air Filter Element Replacement

Check mark

Warning: Ensure the compressor is stopped and voltage is switched off before proceeding.

Check mark

Compressor stopped and voltage switched off?

Check mark

Remove the cover of the air filter (AF) by turning it anti clockwise.

Check mark

Air filter cover removed?

Check mark

Remove the filter element.

Check mark

Filter element removed?

Check mark

Fit the new element and the cover.

Check mark

New element and cover fitted?

Check mark

Reset the air filter service warning.

Run this procedureArrow right

4000 Hourly / 1 Yearly Cooler Cleaning

Check mark

Stop the compressor, close the air outlet valve and switch off the voltage

Check mark

Cover all parts under the coolers

Check mark

Remove the service plate at the fan compartment

Check mark

Remove dirt from the coolers with a fibre brush. Brush in the direction of the cooling fins

Check mark

Remove dirt from the fan with a fibre brush

Check mark

Clean with an air jet in the reverse direction to normal flow

Check mark

If it is necessary to wash the coolers with a cleaning agent, consult Atlas Copco

Check mark

Mount the service plate (1) at the fan compartment

Check mark

CAUTION! After maintenance on the fan and on the coolers: Remove the loose parts that are used as cover

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Atlas Copco

Explore Other Assets