MaintainX Logo
EnterprisePricing
Atlas Copco

Atlas Copco Portable Inverter Generator P2000i

Need answers fast?
Explore the manual using AI.

Atlas Copco Portable Inverter Generator P2000i
Atlas Copco Portable Inverter Generator P2000i

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Atlas Copco Portable Inverter Generator P2000i

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Atlas Copco Portable Inverter Generator P2000i

Atlas Copco Portable Inverter Generator P2000i

Create an account to install this asset package.

Maintenance Plans for Atlas Copco Portable Inverter Generator Model P2000i

Integrate maintenance plans directly into your work orders in MaintainX.

Initial 20 Hours / 1 Months Engine Oil Replacement

Check mark

WARNING! Avoid draining the engine oil immediately after stopping the engine. The oil is hot and should be handled with care to avoid burns

Check mark

Place the generator on a level surface and warm up the engine for several minutes. Stop the engine and turn the 3 in 1 switch knob and fuel tank cap air vent knob to 'OFF'

Check mark

Remove the screw * and then remove the oil filler decal

Check mark

Remove the oil filler cap

Check mark

Place an oil pan under the engine. Tilt the generator to drain the oil completely

Check mark

NOTICE! Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine

Check mark

Replace the generator to a level surface

Check mark

Add engine oil to the upper level

Check mark

Wipe the cover clean, and and wipe up any spoiled oil

Run this procedureArrow right

1 Daily Portable Inverter Generator Check

Check mark

Check fuel level and leakage

Check mark

Check fuel hose for cracks or damage. Replace if necessary

Check mark

Check oil level in engine

Run this procedureArrow right

300 Hourly / 12 Monthly Portable Inverter Generator Maintenance

Check mark

Check hose weather for cracks or damages. Replace if necessary

Check mark

Decarbonize cylinder head. More frequently is necessary

Check mark

Check and adjust valve clearance when engine is cold

Check mark

Check all fittings and fasteners. Correct if necessary

Check mark

Sign off on the generator maintenance

Run this procedureArrow right

100 Hourly / 6 Monthly Spark Plug Inspection

Check mark

Spark Plug Removal

Check mark

Cap I and spark plug cap 2 removed

Check mark

Tool 4 inserted through the hole from the outside of the cover

Check mark

Handlebar 3 inserted into the tool 4 and turned counterclockwise to remove the spark plug

Check mark

Spark Plug Inspection

Check mark

Spark plug discoloration checked

Check mark

Carbon deposits removed

Check mark

Porcelain insulator around the center electrode of spark plug checked and is a medium to light tan color

Check mark

Spark plug type and gap checked

Run this procedureArrow right

300 Hourly / 12 Monthly Fuel Filter Cleaning

Check mark

Remove the screws remove the cover, and then drain the fuel

Check mark

Hold and move up the clamp, then take off the hose from the tank

Check mark

Take out the fuel filter

Check mark

Clean the filter with gasoline

Check mark

Dry the filter and replace

Check mark

Install the hose and clamp, then open the fuel valve to check for leaks

Check mark

Install the cover and tighten the screws

Check mark

Sign off on the fuel filter cleaning

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Atlas Copco

Explore Other Assets