

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

York Rooftop Unit DJ150N32S4BBC2A
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Pilot Flame Check
Pilot Flame Adjustment
Remove pilot adjustment cover screw
Adjust the clearance for air to the desired level
Replace cover screw after adjustment
Pilot Flame Observation
Does the pilot flame envelope the end of the flame sensor?
Put the system into operation
Observe and note any issues during the complete cycle
Manufold Gas pressure Adjustment
Preparation
Ensure the furnace is turned off before starting the adjustment
Gather necessary tools for adjustment
Adjustment Procedure
Remove the cap on the regulator located next to the push-on electrical terminals
Measure the current manifold gas pressure
Adjust the gas pressure
Measure the manifold gas pressure after adjustment
Is the manifold pressure within the correct range of 3.65 IWG ±0.3?
Burner Maintenance
Burner Instructions
Close main manual shut-off valve and shut off all electric power to the unit
Remove the screws holding either end of the manifold to the burner supports
Open the union fitting in the gas supply line just upstream of the unit gas valve and downstream from the main manual shut-off valve
Remove the gas piping closure panel
Disconnect wiring to the gas valves and spark ignitors
Remove the manifold-burner gas valve assembly by lifting up and pulling back
Ensure burners are accessible for service
Reverse the procedure to replace the assemblies
Rooftop Unit Prestart Check
Prestart Checklist - Cooling
Check the electrical supply voltage being supplied
Is the electrical supply voltage the same as listed on the unit nameplate?
Set the room thermostat to the off position
Turn unit electrical power on
Set the room thermostat fan switch to on
Is the indoor blower rotation correct?
Check blower drive belt tension
Check the unit supply air (CFM)
Gas Input Check
Preparation
Turn off all other gas appliances connected to the gas meter
Measurement
Measure the time needed for one revolution of the hand on the smallest dial on the meter with the furnace turned on
Enter the size of the test dial (1/2 or 1 cubic foot)
Calculation
Enter the number of seconds for one revolution
Enter the furnace rating in Btuh
Enter the Btu content of the gas in your locality
Access the parts list for your equipment in MaintainX.
Optional CO2 Space Sensor Kit
2AQ04700224
Optional CO2 Sensor Kit
2AQ04700124
Optional CO2 Space Sensor Kit
2AQ04700224
Optional CO2 Sensor Kit
2AQ04700124
Optional CO2 Space Sensor Kit
2AQ04700224
Optional CO2 Sensor Kit
2AQ04700124
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













