MaintainX Asset Hub logo
EnterprisePricing
Whitehall Manufacturing

Whitehall Manufacturing Whirlpool WHE-27-M

Need answers fast?
Explore the manual using AI.

Whitehall Manufacturing Whirlpool WHE-27-M
Whitehall Manufacturing Whirlpool WHE-27-M

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Whitehall Manufacturing Whirlpool WHE-27-M

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Whitehall Manufacturing Whirlpool WHE-27-M

Whitehall Manufacturing Whirlpool WHE-27-M

Create an account to install this asset package.

Maintenance Plans for Whitehall Manufacturing Whirlpool Model WHE-27-M

Integrate maintenance plans directly into your work orders in MaintainX.

Whirlpool Draining

Check mark

Preparation

Check mark

Turn the turbine power switch (13) off to stop water circulation.

Check mark

Draining without separate drain pump

Check mark

Select draining method

Check mark

Using a floor drain

Check mark

Connect hose to drain valve (15).

Check mark

Open the drain valve (15).

Check mark

Using a sink

Check mark

Rotate pressure control valve (11) counterclockwise.

Run this procedureArrow right

Whirlpool Cleaning

Check mark

Preparation

Check mark

Ensure cleaning materials are ready

Check mark

Cleaning Instructions

Check mark

Disinfect and clean the tub after each user

Check mark

Disinfect and clean the thermometer after each user

Check mark

Disinfect and clean the turbine after each user

Check mark

Material Safety

Check mark

Avoid using abrasive compounds or metal brushes

Check mark

Ensure steel wool does not contact stainless steel

Run this procedureArrow right

Tub And Thermometer Cleaning

Check mark

Preparation

Check mark

Drain the tub following the draining instructions above.

Check mark

Verify that the turbine is off.

Check mark

Cleaning the Tub

Check mark

Remove any loose objects or debris from the Whirlpool tub.

Check mark

Select the cleaning material used for disinfecting

Check mark

Disinfect the tub using the selected material per the manufacturer’s instructions.

Check mark

Select the cleaning material used for cleaning

Check mark

Clean the tub using the selected material.

Run this procedureArrow right

12 Monthly Thermometer Adjustment

Check mark

Preparation

Check mark

Fill the tub with water to immerse the thermometer tip at least 10.2 cm (4 inches) deep.

Check mark

Calibration Process

Check mark

Place the stem tip of a calibrated thermometer next to the tip of the Whirlpool thermometer.

Check mark

Turn on the turbine assembly.

Check mark

Is the reading on the Whirlpool thermometer the same as the calibrated thermometer?

Check mark

Adjust the external adjustment screw (a) to match the Whirlpool thermometer reading with the calibrated thermometer, if necessary.

Check mark

Re-calibration Frequency

Check mark

Ensure re-calibration is performed at least every 12 months or as needed.

Run this procedureArrow right

Turbine Cleaning

Check mark

Preparation

Check mark

Drain the tub following the draining instructions above.

Check mark

For tubs greater than 75.7 L (20 US gallons), prepare the turbine

Check mark

Disinfecting Process

Check mark

Fill the bucket or tub with water so the bottom of the turbine is at least 15.2 cm (6 inches) below the surface of the water.

Check mark

Add a disinfectant solution to the water per manufacturer’s instructions.

Check mark

Ensure the pressure control valve is in the open position.

Check mark

Turn on the turbine for 5 seconds and turn it off.

Check mark

Wait 10 minutes.

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Whitehall Manufacturing

Explore Other Assets