MaintainX Logo
EnterprisePricing
Schulz

Schulz Air Compressor SRP4125FLEX

Need answers fast?
Explore the manual using AI.

Schulz Air Compressor SRP4125FLEX
Schulz Air Compressor SRP4125FLEX

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Schulz Air Compressor SRP4125FLEX

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Schulz Air Compressor SRP4125FLEX

Schulz Air Compressor SRP4125FLEX

Create an account to install this asset package.

Maintenance Plans for Schulz Air Compressor Model SRP4125FLEX

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Air Compressor Maintenance

Check mark

PROCEDURES BEFORE BEGINNING MAINTENANCE

Check mark

ATTENTION: There are hot surfaces inside the compressor cabinet after its stop. The use of Schulz genuine lubricant oil and parts extends the useful life of your compressor, preventing, thus, the loss of the Warranty of you compressor.

Check mark

Disconnect the compressor and make sure the tank has no pressure (wait for five minutes)

Check mark

Disconnect the compressor from the power supply (disconnecting switch) and make sure the compressor cannot be inadvertently turned on

Check mark

For compressors with remote command the used in group, you must put up a sign “In Service”, on the start switch

Check mark

Close the valve between the compressed air system and the compressor

Check mark

Maintenance Tasks

Check mark

Inspect the safety valve

Check mark

Replace coalescing pre-filter element*

Run this procedureArrow right

4000 Hourly Air Compressor Maintenance

Check mark

PROCEDURES BEFORE BEGINNING MAINTENANCE

Check mark

ATTENTION

Check mark

There are hot surfaces inside the compressor cabinet after its stop.

Check mark

The use of Schulz genuine lubricant oil and parts extends the useful life of your compressor, preventing, thus, the loss of the Warranty of you compressor.

Check mark

A. Disconnect the compressor and make sure the tank has no pressure (wait for five minutes)

Check mark

B. Disconnect the compressor from the power supply (disconnecting switch) and make sure the compressor cannot be inadvertently turned on

Check mark

For compressors with remote command the used in group, you must put up a sign “In Service”, on the start switch

Check mark

C. Close the valve between the compressed air system and the compressor

Check mark

1. Change lubricant oil mineral 4000*(8)

Run this procedureArrow right

2000 Hourly Air Compressor Maintenance

Check mark

PROCEDURES BEFORE BEGINNING MAINTENANCE

Check mark

ATTENTION: There are hot surfaces inside the compressor cabinet after its stop. The use of Schulz genuine lubricant oil and parts extends the useful life of your compressor, preventing, thus, the loss of the Warranty of you compressor.

Check mark

Disconnect the compressor and make sure the tank has no pressure (wait for five minutes)

Check mark

Disconnect the compressor from the power supply (disconnecting switch) and make sure the compressor cannot be inadvertently turned on

Check mark

For compressors with remote command the used in group, you must put up a sign “In Service”, on the start switch

Check mark

Close the valve between the compressed air system and the compressor

Check mark

PROCEDURE FOR REPLACEMENT OF THE OIL FILTER

Check mark

Remove the used element 1.

Check mark

Install new component 1.

Run this procedureArrow right

Air Compressor Maintenance

Check mark

PROCEDURES BEFORE BEGINNING MAINTENANCE

Check mark

ATTENTION: There are hot surfaces inside the compressor cabinet after its stop. The use of Schulz genuine lubricant oil and parts extends the useful life of your compressor, preventing, thus, the loss of the Warranty of you compressor.

Check mark

Disconnect the compressor and make sure the tank has no pressure (wait for five minutes)

Check mark

Disconnect the compressor from the power supply (disconnecting switch) and make sure the compressor cannot be inadvertently turned on

Check mark

For compressors with remote command the used in group, you must put up a sign “In Service”, on the start switch

Check mark

Close the valve between the compressed air system and the compressor

Check mark

Maintenance Tasks

Check mark

Clean the radiator and the condenser externally*(4)

Check mark

Tighten screws*(4)

Run this procedureArrow right

8000 Hourly Air Compressor Maintenance

Check mark

PROCEDURES BEFORE BEGINNING MAINTENANCE

Check mark

ATTENTION: There are hot surfaces inside the compressor cabinet after its stop. The use of Schulz genuine lubricant oil and parts extends the useful life of your compressor, preventing, thus, the loss of the Warranty of you compressor.

Check mark

Disconnect the compressor and make sure the tank has no pressure (wait for five minutes)

Check mark

Disconnect the compressor from the power supply (disconnecting switch) and make sure the compressor cannot be inadvertently turned on

Check mark

For compressors with remote command the used in group, you must put up a sign “In Service”, on the start switch

Check mark

Close the valve between the compressed air system and the compressor

Check mark

1. Change lubricant oil synthetic 8000*(8)

Check mark

PROCEDURE FOR CHANGING THE LUBRICANT OIL

Check mark

Turn off the compressor and wait for at least 5 (five) minutes for the elimination of the pressure of the system

Run this procedureArrow right

Parts for Schulz Air Compressor SRP4125FLEX

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Lubricant Oil Lub Schulz Mineral 1000 (Drum 20 Liters)

101.0173-0

Lubricant Oil Lub Schulz Mineral 4000 (Drum 20 Liters)

101.0280-0/AT

Lubricant Oil Lub Schulz Synthetic 8000 (Drum 20 Liters)

101.0239-0/AT

Air Filter Element (Primary)

007.0364-0/AT

Air Filter Element (Secondary)

007.0365-0/AT

Lubricant Oil Lub Schulz Mineral 1000 (Drum 20 Liters)

101.0173-0

Lubricant Oil Lub Schulz Mineral 4000 (Drum 20 Liters)

101.0280-0/AT

Lubricant Oil Lub Schulz Synthetic 8000 (Drum 20 Liters)

101.0239-0/AT

Air Filter Element (Primary)

007.0364-0/AT

Air Filter Element (Secondary)

007.0365-0/AT

Lubricant Oil Lub Schulz Mineral 1000 (Drum 20 Liters)

101.0173-0

Lubricant Oil Lub Schulz Mineral 4000 (Drum 20 Liters)

101.0280-0/AT

Lubricant Oil Lub Schulz Synthetic 8000 (Drum 20 Liters)

101.0239-0/AT

Air Filter Element (Primary)

007.0364-0/AT

Air Filter Element (Secondary)

007.0365-0/AT

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Schulz

Explore Other Assets