The Panasonic IGBT Controlled Plasma Arc Cutting Power Source YP-060PF is a high-performance industrial tool designed for precision cutting applications. With advanced IGBT technology, this power source ensures efficient operation and reliability, making it ideal for various metal fabrication tasks.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Panasonic IGBT Controlled Plasma Arc Cutting Power Source YP-060PF
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Check 1D
• Perform the daily check without fail. It is important to make the most of the performance of this product and to secure the safety of daily operations.
• Check the items indicated in the “Table 1” and “Table 2”, and conduct the cleaning and replacement of parts if necessary.
• For replacement of parts, make sure to use our genuine parts for Panasonic air plasma cutting torch to keep its performance and functions
12.1.1 The cutting machine (the Product)
Table 1
Operation panel
• The category of switch
Operation, switching sense and loose attachment.
• LED is lit and goes off reliably.
Inspection
Focus the confirmation on the below mentioned items.
· Check if there is any trace of heat generation, such as discoloration, odor and loose connection inside the machine. If it happens, please fasten them.
· Items which daily spot check cannot be covered.
For output side, base metal side, input side cable and grounding wire, execute confirmation on inspection for the key points mentioned on the routine inspection chapters and the items which are not covered on routine inspection.
· The such part as printed circuit board etc. use relay, of which the “contact” switches the circuit. A certain electrical and mechanical service life should be considered. The cooling fan and electrolytic capacitor also have certain service life.
When conducting inspection or maintenance, treat the cooling fan and electrolytic capacitor as consumable parts as they have a given electrical and mechanical life respectively.
For example, when they are used under the rated specifications, the life of the cooling fan is about 40000 hours, and that of the electrolytic capacitor of YP-100PF is about 102100 hours, YP-060PF electrolytic capacitor about 68708 hours. Their actual duration depends on how those items are used by customers. Therefore we cannot take the measurement with how many years and months and please take them as consumable parts and execute inspection and maintenance.;
Inspection 1M
While details for checking are shown below table, consider any additional check items according to your conditions of use.
If there is a mass of dust and amount of contaminant which can pose great impact on the performance of the Product, please adjust the frequency according to the inspection results.
· the cleaning of drain valve and parts of the air filter;
Inspection 3M
· Daily checks are not enough to keep the proper performance of this product for a long time. Perform the periodic check without fail. It is important to keep the proper performance of this product for a long time.
· In the periodic check, after cutting off power source check the product thoroughly including checking and cleaning of the inside of this product.
· Except the cleanness of water filter, conduct the periodic check every 6 months normally. If there is a mass of fine dust, oily smoke, etc. Around this product, perform the regular check every month as a guideline).
· Please record the executed date of the inspection and cleanness on the data plate (Fig. 1) on the right side of the power source.
Please periodically execute (every 3 ~ 6 months) inspection and cleanness inside the cutting machine.(year/month/date)
(For detailed inspection contents, please refer to the operational manual of the product.);
Inspection 6M
· removal of the dust inside cutting machine
· cutting machine allover inspection
· inspection on the cable and grounding wire;
Access the parts list for your equipment in MaintainX.
Air filter
AF20-02BC-A
Air regulator rotary knob
RA800-8PB
Air valve
J54×2
Air valve
J540-745G
Bridge Rectifier
MDS60-16W
Air filter
AF20-02BC-A
Air regulator rotary knob
RA800-8PB
Air valve
J54×2
Air valve
J540-745G
Bridge Rectifier
MDS60-16W
Air filter
AF20-02BC-A
Air regulator rotary knob
RA800-8PB
Air valve
J54×2
Air valve
J540-745G
Bridge Rectifier
MDS60-16W
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX