Nihon Kohden Corporation Portable Defibrillator TEC7100/7200U
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Battery Maintenance
Inspection
Visually inspect the battery for any damage such as cracks, deformations, or electrolyte leakage on the terminals.
Is the battery in need of replacement?
Clean the battery if it is dirty.
Maintenance
Store the spare battery in a dry, cool place.
Is the battery fully charged before storing?
Safety Precautions
Clean the battery with a clean cloth, avoiding organic solvents such as gasoline, thinner, or oils.
Paddles Maintenance
Cleaning the Paddles
Remove contact gel completely from the paddle electrode faces
Remove dirt completely from inside the paddle housing with a clean cloth
Disinfection and Sterilization of the External Paddles
Ensure external paddles are not exposed to heat over 60 °C
Ensure external paddles are not dipped into water or other liquids
Select suitable sterilization methods for external paddles
Disinfection and Sterilization of the Internal Paddles
Select suitable sterilization methods for internal paddles
1 Monthly Discharge Inspection
WARNING: Do not use contact gel when performing the discharge test.
Initial Setup
Set the ENERGY SELECT dial to 'ECG MON ON' position to activate the self-diagnostic function.
Did the 'READY' message appear on the CRT screen?
Test Mode Selection
Select the TEST mode using the LEAD select key.
Press the SYNC MODE select key to illuminate the SYNC mode indicator lamp.
Synchronization Check
Verify that spots indicating synchronization positions appear at the rising portions of the ECG simulated waveforms and a sound synchronized with the waveform is emitted.
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX