The Nidec Refractive Power / Corneal Analyzer OPD-SCAN III is a cutting-edge diagnostic tool designed for precise corneal analysis. This advanced equipment enhances clinical efficiency and accuracy, making it essential for eye care professionals seeking reliable performance in vision assessment.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Nidec Refractive Power / Corneal Analyzer OPD-SCAN III
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Printer Cleaning
Warning: This procedure requires trained personnel!
Printer cover opened and paper roll removed?
Applied vacuum cleaner to the auto cutter to remove paper residue?
Warning: Never blow off paper residue with a blower. If residue settles on the internal working structure, malfunction may result.
Printer paper supplied as it was?
Sign off on the printer cleaning
Printer Cover Cleaning
Warning: Never use an organic solvent such as paint thinner. This could damage the surface of the device
Warning: Do not press the LCD using an object with a hard tip. Keep magnetic objects away from the LCD
Warning: Never use a sponge or cloth soaked in water. The water may leak into the inside of the device and cause device failure
Clean printer cover with a soft cloth
For persistent stains, clean with a cloth soaked in a neutral detergent and dried well
Dry the cover with a soft, dry cloth
Lightly wipe the exterior of the LCD
Check for smudge on the measuring window before use
Blow off dust on the measuring window with a blower
Printer Paper Replacement
Warning: Do not run the printer when printer paper is not loaded. It may ruin the printer head; Do not pull the paper in the printer forcefully. This may cause malfunction of the printer
Red line appears on the side of the printer paper?
If red line appears, stop using the printer and replace the roll with a new one
Press the cover open button to open the printer cover
Remove the used printer paper
CAUTION: When replacing printer paper, be sure not to touch the printer head on the upper part inside printer cover. The printer head is extremely hot immediately after printing. Injury may occur
Set new printer paper. Set paper as shown in the picture to the right. Leave the end of paper out from the cover
Note: If the roll is set upside down, printing will not occur. Make sure that the printer paper roll is not tilted or the shaft misaligned. The paper will not be properly fed
Close the printer cover. Press the right and left sides of the printer cover to close the printer
Printer Touch Screen Calibration
Warning: Calibration requires precision. Use the provided touch pen.
Is the touch pen ready?
Press the Maintenance button on the Main Menu screen to display the Maintenance screen.
Press the Touch-Screen Calibration button to start the calibration.
A message will appear in the center of the screen, and a cross mark will appear in the upper left corner of the screen. Touch the center of the cross mark using the touch pen.
Did you touch the cross mark within 20 seconds?
The display position of the cross mark will change to the lower left corner of the screen. Touch the center of the cross mark using the touch pen.
Touch the centers of the cross marks displayed in the upper and lower right corners of the screen using the touch pen.
Did you touch the center of the cross mark in the lower right corner of the screen?
Priter Accuracy Check
Warning: This procedure requires trained personnel!
Remove the stack of chinrest paper from the chinrest
Remove the cap from the spherical model eye
Place the model eye on the chinrest with its lens toward the measuring window
Insert the fixing pins
Align the level of the spherical model eye with the eye level marker
Set “Display/Print Format - Step” on the Settings screen (Other tab) to “0.01”
Perform OPD and CT measurements in the same manner as the normal OPD and CT measurements
Enter the measurement values and the values marked on the model eye
Access the parts list for your equipment in MaintainX.
Chinrest Paper
32903-M047
Printer Paper
80620-00001
Chinrest Paper
32903-M047
Printer Paper
80620-00001
Chinrest Paper
32903-M047
Printer Paper
80620-00001
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX