MaintainX Asset Hub logo
EnterprisePricing
Mori Seiki

Mori Seiki CNC Lathe DuraTurn 2050

Need answers fast?
Explore the manual using AI.

Mori Seiki CNC Lathe DuraTurn 2050
Mori Seiki CNC Lathe DuraTurn 2050

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Mori Seiki CNC Lathe DuraTurn 2050

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Mori Seiki CNC Lathe DuraTurn 2050

Mori Seiki CNC Lathe DuraTurn 2050

Create an account to install this asset package.

Maintenance Plans for Mori Seiki CNC Lathe Model DuraTurn 2050

Integrate maintenance plans directly into your work orders in MaintainX.

1000 Hourly Electrical Cabinet Fan and Filter Cleaning

Check mark

WARNING! Turn OFF the main power and disconnect the plantside power supply (breaker). Use a ladder or service platform when working in elevated places. Loss of balance may result in serious injury

Check mark

CAUTION! If foreign matter adheres to the fan, it impairs cooling performance. Clean the fan periodically. Dust and dirt may damage the filter and prevent air flow. Clean the filter periodically. Do not wash the filter by hand. The filter may gradually deteriorate after being cleaned about 5 - 10 times. If the filter deteriorates, replace it with a new filter

Check mark

Turn OFF the main power

Check mark

Disconnect the plant-side power supply (breaker)

Check mark

Remove the side cover

Check mark

Remove the power connector

Check mark

Remove the fan guard

Check mark

NOTE! Take care not to let the fan body fall when the screws are removed

Check mark

Clean the fan guard and fan

Run this procedureArrow right

1000 Hourly Hydraulic Unit Oil Replacement

Check mark

Main power turned OFF?

Check mark

Fill port cap removed?

Check mark

Drain pan placed beneath the drain plug?

Check mark

Drain plug removed and oil drained?

Check mark

Drain plug replaced?

Check mark

Enter the oil level gage reading

Check mark

Fill port cap replaced?

Check mark

Main power turned ON?

Check mark

Pump pressure and suction noise are normal?

Run this procedureArrow right

1000 Hourly Lubricant Tank Cleaning

Check mark

WARNING! Turn OFF the main power

Check mark

Main power turned OFF

Check mark

Suction filter and fill port filter removed

Check mark

CAUTION! Protective glasses must be worn to prevent eye damage form dust or foreign matter (those who are wearing glasses included)

Check mark

Inside of the tank cleaned with a neutral detergent

Check mark

Lubricating unit remounted

Check mark

Lubricant supplied

Check mark

Sign off on the lubricant tank cleaning

Run this procedureArrow right

1000 Hourly Pneumatic Device Filter Inspection

Check mark

WARNING! Turn OFF the main power

Check mark

Turn OFF the main power

Check mark

Rotate the valve CW to shut off the compressed air supply

Check mark

Turn the manual drain cock in the counterclockwise direction to release residual pressure

Check mark

Confirm the pressure gage indicates 0 MPa

Check mark

Inspect/replace the air filter element

Check mark

Removing Air Filter Assembly Case

Check mark

Slide the lock button downward and rotate the assembly case 45 degrees CW or CCW

Check mark

Pull the assembly case downward to remove

Run this procedureArrow right

1000 Hourly Suction Strainer and Tank Cleaning

Check mark

1) Turn OFF the main power

Check mark

2) Drain oil in the tank

Check mark

NOTE! Refer to the steps 3) - 5) in "Replacing Oil" (page 2-346)

Check mark

3) Remove the bolts beneath the tank and pull the hydraulic unit out from the base

Check mark

4) Loosen the hose band

Check mark

5) Disconnect the piping

Check mark

6) Remove the tank upper plate

Check mark

7) Clean the suction strainer using the following procedure

Check mark

a) Remove the suction strainer

Run this procedureArrow right

Parts for Mori Seiki CNC Lathe DuraTurn 2050

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

192 MB ATA Flash Memory Card

E77102

1 GB CF Card

E77105

256 MB CF Card

E77104

28 MB CF Card

E77101

640 MB ATA Flash Memory Card

E77103

192 MB ATA Flash Memory Card

E77102

1 GB CF Card

E77105

256 MB CF Card

E77104

28 MB CF Card

E77101

640 MB ATA Flash Memory Card

E77103

192 MB ATA Flash Memory Card

E77102

1 GB CF Card

E77105

256 MB CF Card

E77104

28 MB CF Card

E77101

640 MB ATA Flash Memory Card

E77103

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Mori Seiki

Explore Other Assets