Mitsubishi Outdoor Unit MUZ-HM24NA
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Defrost Setting Changing
Warning: This procedure requires technical knowledge and should be performed by trained personnel only.
JS wire of the outdoor inverter P.C. board identified?
Choose the current setting of JS wire
Choose the model of the unit
Choose the desired defrost finish temperature
JS wire cut/soldered as per the desired setting?
Sign off on the defrost setting change
Pre-Heat Control Setting
Warning: This procedure requires trained personnel with PPE!
Enter the discharge temperature thermistor reading
If the discharge temperature thermistor is 68°F (20°C) or below, the pre-heat control turns ON.
Choose the pre-heat control setting
To activate the pre-heat control, cut JK wire of the inverter P.C. board.
To deactivate the pre-heat control, solder JK wire of the inverter P.C. board.
Check if the inverter P.C. board is replaced
If the inverter P.C. board is replaced, check the jumper wires, and cut/solder them if necessary.
Sign off on the pre-heat control setting
Access the parts list for your equipment in MaintainX.
4-Way Valve
E22 A56 961
Ambient Temperature Thermistor, Symbol - RT65
E22 G16 309
Back Panel
E22 N94 233
Base
E22 F28 290
Cabinet
E22 N94 232
4-Way Valve
E22 A56 961
Ambient Temperature Thermistor, Symbol - RT65
E22 G16 309
Back Panel
E22 N94 233
Base
E22 F28 290
Cabinet
E22 N94 232
4-Way Valve
E22 A56 961
Ambient Temperature Thermistor, Symbol - RT65
E22 G16 309
Back Panel
E22 N94 233
Base
E22 F28 290
Cabinet
E22 N94 232
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX