Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Mitsubishi Split-Type, Heat Pump Air Conditioner PUHZ-RP200YKAR1
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Outdoor Unit Refrigirant Charging
Cautions for service
Refrigerant recovered from the unit completely
Refrigerant not released in the air
Cycle charged with specified amount of refrigerant after service
Filter drier installed for new refrigerant
Additional refrigerant charge
Cylinder for R410A is a syphon type
Charging performed with the cylinder of syphon stood vertically
Service tools
Outdoor Unit the 4-Way Valve Coil (21S4) and Linear Expansion Valve Coil (LEV-A, LEV-B) Replacement
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove the electrical parts box. (See Photo 4)
[Removing the 4-way valve coil]
(4) Remove 4-way valve coil fixing screw (M4 × 6).
(5) Remove the 4-way valve coil by sliding the coil toward you.
[Removing the linear expansion valve coil]
(4) Remove 3 right side panel fixing screws (5 × 10) in the rear of the unit then remove the right side panel.
(5) Remove the linear expansion valve coil by sliding the coil upward.;
Outdoor Unit Fan Motor (MF1, MF2) Replacement
Remove the service panel
Upload a photo of the service panel removal
Remove the top panel
Upload a photo of the top panel removal
Remove 4 fan grille fixing screws (5 × 10) to detach the fan grille
Upload a photo of the fan grille removal
Remove a nut (for right handed screw of M6) to detach the propeller
Upload a photo of the propeller removal
Disconnect the connectors, CNF1, CNF2 on controller circuit board in electrical parts box
Outdoor Unit Compressor (MC) Replacement
Remove the service panel
Remove the top panel
Remove 2 front cover panel fixing screws (5 × 10) and remove the front cover panel
Remove 4 back cover panel fixing screws (5 × 10) and remove the back cover panel
Remove the electrical parts box
Remove 3 valve bed fixing screws (4 × 10), 4 ball valve and stop valve fixing screws (5 × 16), then remove the valve bed
Remove 3 right side panel fixing screws (5 × 10) in the rear of the unit and remove the right side panel
Remove 3 separator fixing screws (4 × 10) and remove the separator
Remove the soundproof cover for compressor
Outdoor Unit 4-Way Valve Replacement
Remove the service panel
Upload a photo of the removed service panel
Remove the top panel
Upload a photo of the removed top panel
Remove the electrical parts box
Upload a photo of the removed electrical parts box
Remove 3 valve bed fixing screws, 4 ball valve and stop valve fixing screws then remove the valve bed
Remove 3 right side panel fixing screws in the rear of the unit then remove the right side panel
Remove the 4-way valve coil
Access the parts list for your equipment in MaintainX.
Inverter Starter Type, Hermetic Compressor - 4,7 KW
ANB52FFQMT
Inverter Starter Type, Hermetic Compressor - 4,7 KW
ANB52FFQMT
Inverter Starter Type, Hermetic Compressor - 4,7 KW
ANB52FFQMT
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX