Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Mitsubishi Air Conditioner PURY-EP250YLM-A
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
BC Controller Pressure Sensor Disassembling
(1) Remove the service panel.
1) For the pressure sensors PS1 and PS3, refer to 1. 1), 2).
(2) Remove the pressure sensor connector in trouble from the control board, and insulate the connector.
1) Liquid-side pressure sensor (CNP1).
2) Intermediate-part pressure sensor (CNP3).
(3) Attach a new pressure sensor to the place which is shown in the figure, and insert the connector to the control board.
Note.
When gas leaks from the pressure sensor, repair the leak, and follow the instructions above if required.;
BC Controller LEV Disassembling
Service panel removed
LEV replaced
Note: Secure enough service space in the ceiling for welding operation, and conduct the work carefully. If required, dismount the unit from the ceiling, and conduct the work.
Sign off on the disassembling process
Compressor Disassembling
Remove both the top and bottom service panels (front panels)
Remove the control box and the compressor cover (front)
Remove the wires that are secured to the frame,and remove the frame
Remove the compressor cover (top)
Remove the compressor wires, compressor cover, and the right
Place protective materials on the insulation lining of the compressor cover and on the sealing material, on the compressor suction pipe to protect them from the torch flame, debraze the pipe, and replace the compressor
Sign off on the compressor disassembling
Check Valve Disassembling
Instructions for replacing service parts for Solenoid valve block ASSY (SV4a, SV4b, SV4d), Check valve (CV4a, CV6a, CV8a, CV9a)
Parts to be serviced
Select the check valve to be serviced
Precautions for starting replacement
Main power supply is OFF
No refrigerant in the outdoor unit
Check valve (CV4a, CV6a, CV8a, CV9a) replacement procedures
Solenoid valve block ASSY removed
I-L parts debrazed and Check valve ASSY removed
Solenoid Valve Block Disassembling
Warning: This procedure requires trained personnel with PPE!
Is the main power supply OFF?
Is there no refrigerant in the outdoor unit?
Remove each part according to the 1)-3) procedures on the figure above right before replacing service parts.
Mount the removed parts back in place in a reversed procedure of 1)-3) on the figure next page after replacing service parts.
Solenoid valve block ASSY (SV4a, SV4b, SV4d) replacement procedures.
To remove Solenoid valve block ASSY.
Solenoid valve block coil cover, Solenoid valve coil, and peripheral cables removed?
Screw (M5) that fixes the supporting plate for Solenoid valve block and the unit base removed?
Access the parts list for your equipment in MaintainX.
Solenoid Valve Block Service Parts Set - SV4a, SV4b, SV4d
KB00S879G30
Solenoid Valve Block Service Replacement Instructions - SV4a, SV4b, SV4d
WT07372X01
Solenoid valve block ASSY - SV4a, SV4b, SV4d
KB00V531G01
Check Valve Service Parts Replacement Instructions Set - CV4a,CV8a
KB00S879G32
Check Valve Replacement Instructions - CV4a,CV8a
WT07372X01
Solenoid Valve Block Service Parts Set - SV4a, SV4b, SV4d
KB00S879G30
Solenoid Valve Block Service Replacement Instructions - SV4a, SV4b, SV4d
WT07372X01
Solenoid valve block ASSY - SV4a, SV4b, SV4d
KB00V531G01
Check Valve Service Parts Replacement Instructions Set - CV4a,CV8a
KB00S879G32
Check Valve Replacement Instructions - CV4a,CV8a
WT07372X01
Solenoid Valve Block Service Parts Set - SV4a, SV4b, SV4d
KB00S879G30
Solenoid Valve Block Service Replacement Instructions - SV4a, SV4b, SV4d
WT07372X01
Solenoid valve block ASSY - SV4a, SV4b, SV4d
KB00V531G01
Check Valve Service Parts Replacement Instructions Set - CV4a,CV8a
KB00S879G32
Check Valve Replacement Instructions - CV4a,CV8a
WT07372X01
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX