MAMAC Systems Low Pressure Sensor PR-275-R3-VDC

Need answers fast?
Explore the manual using AI.

MAMAC Systems Low Pressure Sensor PR-275-R3-VDC
MAMAC Systems Low Pressure Sensor PR-275-R3-VDC

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for MAMAC Systems Low Pressure Sensor PR-275-R3-VDC

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

MAMAC Systems Low Pressure Sensor PR-275-R3-VDC

MAMAC Systems Low Pressure Sensor PR-275-R3-VDC

Create an account to install this asset package.

Maintenance Plans for MAMAC Systems Low Pressure Sensor Model PR-275-R3-VDC

Integrate maintenance plans directly into your work orders in MaintainX.

Low Pressure Sensor Checkout

Check mark

Verify that the unit is mounted in the correct position

Check mark

Verify appropriate input signal and supply voltage

Check mark

Caution: Never connect 120 VAC to these transducers. Never connect AC voltage to a unit intended for DC supply.

Check mark

Verify appropriate configuration range

Check mark

Transducer Operation

Check mark

Adjust the pressure to obtain maximum output signal for appropriate range

Check mark

Enter the maximum output signal value

Check mark

Is the maximum output signal within the expected range (20 mA or 5 or 10 VDC)?

Check mark

Adjust the pressure to obtain minimum output signal

Run this procedureArrow right

Unit Wiring

Check mark

Caution

Check mark

Ensure the hot wire is on the [+] terminal if using grounded AC.

Check mark

Use an isolation transformer if the controller lacks built-in isolation.

Check mark

Avoid powering from transformers used for non-isolated full-wave rectifier power supplies.

Check mark

Ensure all 24G power leads are connected to the same power lead on all devices when using the same transformer.

Check mark

Maintain correct phasing when powering more than one device from a single transducer.

Check mark

Wiring PR-274/275 Units with VDC Output

Check mark

Remove the terminal block by carefully pulling it off the circuit board.

Check mark

Locate the terminal markings on the board

Run this procedureArrow right

Unit Calibration

Check mark

Calibration of PR-274/275 VDC Units

Check mark

Connect terminals [+] and [-] to the appropriate power source.

Check mark

Connect the DVM on DC volts across [O] and [-] terminal.

Check mark

Repeat low and high pressure calibration steps until desired calibration is achieved.

Check mark

Low Pressure Calibration

Check mark

Select configuration type for low pressure calibration

Check mark

Apply low pressure to the unit.

Check mark

Adjust Zu trimmer for uni-direction or Zb trimmer for bi-direction to achieve desired low output.

Check mark

High Pressure Calibration

Run this procedureArrow right

Low Pressure Sensor Installation

Check mark

Safety Precautions

Check mark

Disconnect power supply before installation to prevent electrical shock and equipment damage.

Check mark

Make all connections in accordance with the job wiring diagram and in accordance with national and local electrical codes. Use copper conductors only.

Check mark

Use electrostatic discharge precautions (e.g., use of wrist straps) during installation and wiring to prevent equipment damage.

Check mark

Avoid locations where severe shock or vibration, excessive moisture or corrosive fumes are present.

Check mark

Ensure NEMA Type 4 housings are used for outdoor installations to provide protection against wind-blown dust, rain, and hose-directed water.

Check mark

Do not exceed ratings of the device.

Check mark

Ensure condensate or moisture does not enter pressure sensor ports.

Check mark

Mounting the Transducer

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from MAMAC Systems

Explore Other Assets