Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Loren Cook Company Ventilation Fan 402SQN-B

Loren Cook Company Ventilation Fan 402SQN-B

Create an account to install this asset package.

Maintenance Plans for Loren Cook Company Ventilation Fan Model 402SQN-B

Integrate maintenance plans directly into your work orders in MaintainX.

Wheel Maintenance

Check mark

Wheel Replacement

Check mark

Drill two 1/4” diameter holes, 180° apart centered approximately between the shaft and the outside diameter of the hub, 3/8” to 1/2” in depth.

Check mark

Tap 1/4” holes to 5/16” thread with a 5/16” hole tap.

Check mark

Screw the puller arms to the full depth of the threads into the tapped holes.

Check mark

Align center of the puller with the center of the shaft.

Check mark

Ensure all setscrews in the hub are fully removed.

Check mark

Slowly remove wheel from the shaft.

Check mark

Recommended Puller

Check mark

Use Lisle No. 45000 Sterling Wheel Puller.

Run this procedureArrow right

6 Monthly Fan Inspection

Check mark

Maintenance

Check mark

Inspect bolts and setscrews for tightness

Check mark

Inspect belt wear and alignment

Check mark

Inspect bearings as recommended in the Conditions chart

Check mark

Inspect for cleanliness

Run this procedureArrow right

Pulley and Belt Maintenence

Check mark

Pulley and Belt Replacement

Check mark

Remove pulleys from their respective shafts

Check mark

Clean the motor and fan shafts

Check mark

Clean bores of pulleys and coat the bores with heavy oil

Check mark

Remove grease, rust, or burrs from the pulleys and shafts

Check mark

Remove burrs from shaft by sanding

Check mark

Place fan pulley on fan shaft and motor pulley on its shaft

Check mark

Tighten in place

Check mark

Install belts on pulleys and align as described in Belt and Pulley Installation

Run this procedureArrow right

6 Monthly Fan Bearing Lubrication

Check mark

Fan Bearings

Check mark

NOTICE!

Check mark

Ensure fan bearings are prelubricated

Check mark

Check for specialized lubrication instructions on fan labels

Check mark

Verify bearing grease is a petroleum lubricant in a lithium base conforming to an NLGI #2 consistency

Check mark

Is the lubricant compatible with the installation?

Check mark

Adjust lubrication interval based on installation conditions

Check mark

Lubricate the bearing while the fan is in operation

Check mark

Pump grease in slowly until a slight bead forms around the bearing seals

Run this procedureArrow right

Initial Fan Check

Check mark

Inspection

Check mark

Stop the fan before inspection

Check mark

Inspect the fan at the following intervals

Check mark

30 Minute Interval

Check mark

Inspect and adjust as necessary

Check mark

Tighten bolts, setscrews, and motor mounting bolts if necessary

Run this procedureArrow right

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Loren Cook Company

Explore Other Assets