Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Lennox Gas Furnace GHR32Q3-75
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Electrical System Inspection
Electrical Inspection
Check all wiring for loose connections
Check circuit breaker located in unit control box
Check for correct voltage at unit (unit operating)
Check to see that heat (if applicable) is operating
Blower Motor Inspection
Motor Nameplate
Actual Amp-Draw
Burner Assembly Cleaning
Preparation
Turn off electrical and gas power supplies to furnace.
Remove upper and lower furnace access panels.
Disassembly
Disconnect and remove intake pipe from air intake fitting.
Mark all gas valve wires and disconnect them from valve.
Remove gas supply line connected to gas valve.
Disconnect gas valve sensing hose from valve.
Remove burner box cover (4 to 6 screws).
1 Monthly Filter Maintenance
Filter Inspection and Cleaning
Inspect filters for dirt and debris
Are the filters reusable foam filters?
Wash reusable foam filters with water and mild detergent
Dry the filters completely before reinstallation
Spray filters with filter handicoater
Filter Replacement
Is filter replacement necessary?
Order the correct replacement filter
Supply Air Blower Maintenance
Supply Air Blower Inspection and Cleaning
Check and clean blower wheel
Verify motors are prelubricated for extended life
Condensate Trap Maintenance
Winterizing the Unit
Shut down the unit for an extended period
Ensure the unit is exposed to sub-freezing temperatures
Drain water from the condensate trap
Draining the Condensate Trap
Locate the 3/8” cap on the bottom corner of the condensate trap
Remove the 3/8” cap to drain the condensate trap
Periodic Maintenance
Periodically drain the condensate trap to ensure proper drainage
Access the parts list for your equipment in MaintainX.
Gas Leak Detector
31B2001
Flame Signal Transducer
78H5401
Filter Handicoater
P-8-5069
14 X 25 Inch Filter
31J81
20 X 25 Inch Filter
P-87831
Gas Leak Detector
31B2001
Flame Signal Transducer
78H5401
Filter Handicoater
P-8-5069
14 X 25 Inch Filter
31J81
20 X 25 Inch Filter
P-87831
Gas Leak Detector
31B2001
Flame Signal Transducer
78H5401
Filter Handicoater
P-8-5069
14 X 25 Inch Filter
31J81
20 X 25 Inch Filter
P-87831
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs