Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Lennox Cooling Unit LCH048
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Condenser Coil Cleaning
All-Aluminum Coils Cleaning
Spray the coil steadily and uniformly from top to bottom with water
Ensure water pressure does not exceed 900 psi
Ensure spray angle does not exceed 45 degrees
Ensure nozzle is at least 12 inches from the coil face
Check for fractures between the fins and refrigerant tubes
Reduce pressure and work cautiously to prevent damage
Fin/Tube Coils Cleaning
Clean condenser coil with detergent or commercial coil cleaner
1 Monthly Condenser Coil Inspeciton
All-Aluminum Coils Inspection
Inspect the condition of the all-aluminum coils
Are the all-aluminum coils clean and free of debris?
Fin/Tube Coils Inspection
Inspect the condition of the fin/tube coils
Are the fin/tube coils clean and free of debris?
Burner Maintenance
Pre-Maintenance Checks
Examine burner flames for proper appearance during the heating season
Examine burners for any deposits or blockage before each heating season
Burner Cleaning Procedure
Turn off both electrical power and gas supply to unit
Remove blower access panel
Remove top burner box panel
Remove two screws securing burners to burner support and lift the burners from the orifices
Clean burners as necessary
Evaporator Coil Maintenance
Inspection and Cleaning
Inspect the evaporator coil for dirt and debris
Clean the coil using mild detergent or commercial coil cleaner
Flushing
Flush the coil with water
Flush the condensate drain with water
Ensure the following are not wet during flushing
Post Maintenance
Is the coil clean and free of debris?
Filter Replacement
Preparation
Ensure the building is unoccupied before starting the filter replacement.
Verify the correct filter size using table 32.
Filter Replacement
Select the unit type and corresponding filter size
Remove the temporary filters from the unit.
Install the approved filters as per local codes or jurisdiction.
Post Replacement Check
Have all temporary filters been replaced with approved filters?
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX