Kaeser Screw Compressor AS31
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1000 Hourly / 1 Weekly Filter Mat Maintenenace
Clean the filter mat every 100 to 300 service hours depending on the dust content of the intake air.
Switch off the compressor (see chapter 8.2).
Lock the main disconnect switch in the "off" position in accordance with applicable lock out/tag out procedures to ensure the compressor does not restart.
Removal and fitting:
Open the snap fasteners (turn the flat-head screw with a screwdriver counter clock- wise 90*) and remove the holding frame.
Fit the holding frame and close the snap fasteners (turn the flat-head screw with a screwdriver clockwise 90° then press until the fasteners snap in).
Cleaning:
Rinse the mat in warm water ( approximately 105°F), if necessary, use a mild detergent soap to rinse out oily dust. The mat can also be tapped, vacuum cleaned or blown out with compressed air (not in excess of 30 psig).
Attention!: If the mat is heavily soiled or has been cleaned often (maximum five times), replace it.;
1000 Hourly Oil Cooler / Aftercooler Cleaning
Warning: Ensure the compressor unit is switched off and locked in the 'off' position before starting.
Vent the compressor unit before starting.
Open the left-hand maintenance and drive access doors.
Open the upper maintenance door and the drive guard.
Unscrew the cover panel.
Isolate the compressor from the compressed air system by closing the isolation shut-off valve.
Insert the maintenance hose into the hose coupling on the aftercooler.
Vent the aftercooler.
Unscrew the pressure line of the pipework from the compressed air connection.
1000 Hourly Oil Filter Change
Hot oil; beware of scalding.
Attention!: Replace the run--in oil filter cartridge with a standard oil filter cartridge (supplied with the compressor) after approximately 200 operating hours.
It is recommended that the oil filter cartridge is replaced every 1000 to 2000 operating hours and always when the oil is changed.
Switch off the compressor with the control switch
Lock the main disconnect in the "off" position in accordance with applicable lock out/tag out procedures to ensure the compressor does not restart.
Lock the isolation shut-off valve in the "closed" position and vent all compressed air trapped between the compressor and the isolation shut-off valve in accordance with applicable lock out/ tag out procedures.
Open the upper maintenance and door and the drive guard.
Open the right-hand maintenance door.
Insert the maintenance hose - with the ball valve closed - in the hose coupling on the oil separator tank.
1 Weekly Oil Level Check
Check the oil level weekly through the oil sight glass when the compressor is shut down.
Is the oil level at the maximum level (center of the top oil sight glass)?
Venting the Compressor Unit:
Is the compressor unit shut down?
Is the main disconnect locked in the 'off' position?
Is the isolation shut-off valve locked in the 'closed' position?
Is all compressed air vented between the compressor and the isolation shut-off valve?
Is the right-hand maintenance door open?
Does the pressure gauge on the oil separator tank indicate zero psig?
1 Yearly Electrical Connection Check
Warning: Non-observance of safety references can lead to accidents causing injury or damage to equipment.
The compressor unit starts automatically after a power failure if the line pressure is lower than the setting on the air pressure switch.
Do not operate the compressor with open maintenance doors as injury could occur from the drive belts and electrical equipment.
Remove all packaging materials, tools and transport securing devices on and in the compressor unit.
The operator of this compressor unit is responsible for its safe operating condition.
Do not operate this compressor unit in locations where heavy dust conditions, poisonous, or inflammable gases could exist.
Do not connect the compressor unit to a supply voltage other than that stated on the nameplate.
Install the compressor unit in a location not subject to freezing temperatures.
If exhaust ducting is provided, this must be at least the cross section of the cooler exhaust area in size and may not exceed the max. allowed pressure drop defined by the manufacturer.
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX