MaintainX Asset Hub logo
EnterprisePricing
Kaeser

Kaeser Air Compressor ASD 40

Need answers fast?
Explore the manual using AI.

Kaeser Air Compressor ASD 40
Kaeser Air Compressor ASD 40

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Kaeser Air Compressor ASD 40

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Kaeser Air Compressor ASD 40

Kaeser Air Compressor ASD 40

Create an account to install this asset package.

Maintenance Plans for Kaeser Air Compressor Model ASD 40

Integrate maintenance plans directly into your work orders in MaintainX.

1000 Hourly Air Filter Check

Check mark

Warning: Ensure the power supply disconnecting device is switched off, locked in the off position, and no voltage is present. The machine should be cooled down.

Check mark

Air filter check

Check mark

Do not clean the air filter element with liquids.

Check mark

Sealing surfaces match each other

Check mark

The use of an unsuitable air filter element can permit dirt to ingress the pressure system and cause damage to the machine.

Check mark

Replacement part used

Check mark

Sign off on the air filter check

Run this procedureArrow right

1000 Hourly Cooler Cleaning

Check mark

Warning: Regular cleaning of the cooler is essential for reliable cooling of the machine and the compressed air.

Check mark

The frequency of cleaning is mainly dependent on local operating conditions.

Check mark

Is the cooler clean?

Check mark

If the cooler is not clean, proceed with the cleaning process.

Check mark

Did the cleaning process go smoothly?

Check mark

If the cleaning process did not go smoothly, report the issues to the maintenance team.

Check mark

Is the cooler leaking?

Check mark

If the cooler is leaking, it results in loss of cooling oil and compressed air. Report the issue to the maintenance team.

Check mark

Sign off on the cooler cleaning

Run this procedureArrow right

1000 Hourly Cooling Air Filter Mat Cleaning

Check mark

Warning: Ensure the machine is switched off before starting the procedure.

Check mark

Filter mat removed from the retaining frame

Check mark

Loose dirt removed from the filter mat

Check mark

Was the filter mat washed with lukewarm water and household detergent?

Check mark

Filter mat replaced if cleaning was not possible or if the change interval has expired

Check mark

Filter mat carefully inserted in the retaining frame

Check mark

Sign off on the filter mat cleaning

Run this procedureArrow right

1000 Hourly Refrigerant Condenser Cleaning

Check mark

Precondition: The power supply disconnecting device is switched off. The disconnecting device is locked in the off position. A check has been made that no voltage is present.

Check mark

Securing screws undone

Check mark

Panel removed

Run this procedureArrow right

1 Weekly Condensate Drain Check

Check mark

Precondition: Machine running under LOAD

Check mark

Visual check: Does condensate flow as soon as the LED illuminates?

Check mark

If condensate does not drain, the condensate drain hose or the drain itself is blocked.

Check mark

Switch off the machine and clean the drain pipe.

Check mark

Condensate drain manual check: Press the «TEST» button and hold for at least 2 seconds.

Check mark

Carry out maintenance on the condensate drain if condensate still does not flow.

Check mark

Collect condensate in a suitable container and dispose of in accordance with environmental regulations.

Check mark

Sign off on the condensate drain check

Run this procedureArrow right

Parts for Kaeser Air Compressor ASD 40

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Aired Installation Kit

4100

Air Filter

1250

Condensate Drain

6500

Condensate Drain

6501

Contactor

3362

Aired Installation Kit

4100

Air Filter

1250

Condensate Drain

6500

Condensate Drain

6501

Contactor

3362

Aired Installation Kit

4100

Air Filter

1250

Condensate Drain

6500

Condensate Drain

6501

Contactor

3362

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Kaeser

Explore Other Assets