Ingersoll Rand Compressor SSR-HXP25
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1000 Hourly / 9 Monthly Motor Lubrication
Warning: This procedure requires trained personnel with PPE!
Improper lubrication can be a cause of motor bearing failure. The quantity of grease added should be carefully controlled.
The smaller motors must be greased with a lesser amount of grease than larger motors.
When regreasing, stop motor. Disconnect power; lock out and tag.
Remove outlet plugs (or spring-loaded grease relief plugs if present). The outlet plug may not be accessible on the fan end of some TEFC motors.
Grease relief along shaft can occur, precluding necessity of removing this plug if inaccessible.
The inlet grease gun fittings and outlet plugs (or spring-loaded reliefs) are located at each end of the motor housing.
The drive end reliefs protrude out the circumference of the lower portion of the end bell near a flange bolt.
The drive end outlet plugs are located just behind the flange in the air intake area at about the 5 or 6 o’clock position.
1200 Hourly / 6 Monthly Coolant Filter Replacement
Warning: This procedure should be performed by trained personnel only.
Is the operating environment clean?
Enter the current hours of operation
If the operating environment is extremely dirty, change V-belts, coolant, filters, and separator elements more frequently.
Is the coolant filter element ready for replacement?
Use a suitable device and loosen the old element. Use drain pan to catch any leakage during removal. Discard old element.
Wipe the sealing surface of the filter housing with a clean, lint-free rag to prevent the entry of dirt into the system.
Remove the replacement element from its protective package. Apply a small amount of clean lubricant on the rubber seal and install the element.
Screw element on until the seal makes contact with the head of the filter housing. Tighten approximately one-half turn additional.
1 Weekly Compressor Inspection
Inspect coolant level
Inspect discharge temperature (air)
Inspect separator element differential
Inspect air filter Delta P (at full load)
2000 Hourly / 6 Monthly Belt Inspection
Inspect V-Belt/Belt Tension
Inspect sheave grooves for foreign material or rubber build-up
Clean and degrease sheaves before installing new belts
Install new belts in the reverse order of disassembly
Ensure new belt is not pried or forced over the sheave grooves
BELT TENSION ADJUSTMENT
Remove the right guard
Apply a force at the center of the sheave span using a tension gauge
Loosen the nut on the pivot bolt located on the left side on the airend if belt tension is incorrect
2000 Hourly / 9 Monthly Motor Lubrication
Warning: Improper lubrication can be a cause of motor bearing failure. The quantity of grease added should be carefully controlled.
The smaller motors must be greased with a lesser amount of grease than larger motors.
When regreasing, stop motor. Disconnect power; lock out and tag.
Remove outlet plugs (or spring-loaded grease relief plugs if present).
The outlet plug may not be accessible on the fan end of some TEFC motors.
Grease relief along shaft can occur, precluding necessity of removing this plug if inaccessible.
The inlet grease gun fittings and outlet plugs (or spring-loaded reliefs) are located at each end of the motor housing.
The drive end reliefs protrude out the circumference of the lower portion of the end bell near a flange bolt.
The drive end outlet plugs are located just behind the flange in the air intake area at about the 5 or 6 o’clock position.
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX