MaintainX Asset Hub logo
EnterprisePricing
Ingersoll Rand

Ingersoll Rand Compressor SSR-EP25

Need answers fast?
Explore the manual using AI.

Ingersoll Rand Compressor SSR-EP25
Ingersoll Rand Compressor SSR-EP25

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Ingersoll Rand Compressor SSR-EP25

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Ingersoll Rand Compressor SSR-EP25

Ingersoll Rand Compressor SSR-EP25

Create an account to install this asset package.

Maintenance Plans for Ingersoll Rand Compressor Model SSR-EP25

Integrate maintenance plans directly into your work orders in MaintainX.

1000 Hourly / 9 Monthly Motor Lubrication

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

Improper lubrication can be a cause of motor bearing failure. The quantity of grease added should be carefully controlled.

Check mark

The smaller motors must be greased with a lesser amount of grease than larger motors.

Check mark

When regreasing, stop motor. Disconnect power; lock out and tag.

Check mark

Outlet plugs (or spring-loaded grease relief plugs if present) removed?

Check mark

The outlet plug may not be accessible on the fan end of some TEFC motors.

Check mark

Grease relief along shaft can occur, precluding necessity of removing this plug if inaccessible.

Check mark

The inlet grease gun fittings and outlet plugs (or spring-loaded reliefs) are located at each end of the motor housing.

Check mark

The drive end reliefs protrude out the circumference of the lower portion of the end bell near a flange bolt.

Run this procedureArrow right

1200 Hourly / 6 Monthly Coolant Filter Replacement

Check mark

Warning: This procedure should be performed by trained personnel only.

Check mark

Is the operating environment clean?

Check mark

Enter the current hours of operation

Check mark

If the operating environment is extremely dirty, change V-belts, coolant, filters, and separator elements more frequently.

Check mark

Is the coolant filter element changed after the first 150 hours of operation and every 1200 hours thereafter?

Check mark

In dirty operation environments the filter should be changed more frequently.

Check mark

Did you use a suitable device and loosen the old element?

Check mark

Did you use a drain pan to catch any leakage during removal?

Check mark

Did you discard the old element?

Run this procedureArrow right

1 Weekly Compressor Inspection

Check mark

Inspect coolant level

Check mark

Enter the discharge temperature (air)

Check mark

Inspect separator element differential

Check mark

Inspect air filter Delta P (at full load)

Run this procedureArrow right

2000 Hourly / 6 Monthly Belt Inspection

Check mark

Inspect V-Belt/Belt Tension

Check mark

Inspect sheave grooves for foreign material or rubber build-up

Check mark

Clean and degrease sheaves before installing new belts

Check mark

Install new belts in the reverse order of disassembly

Check mark

Ensure new belt is not pried or forced over the sheave grooves

Check mark

BELT TENSION ADJUSTMENT

Check mark

Remove the right guard

Check mark

Apply a force at the center of the sheave span using a tension gauge or other calibrated spring

Check mark

Loosen the nut on the pivot bolt located on the left side (nearest the separator tank) on the airend if belt tension is incorrect

Run this procedureArrow right

2000 Hourly / 9 Monthly Motor Lubrication

Check mark

Warning: Improper lubrication can cause motor bearing failure. The quantity of grease added should be carefully controlled.

Check mark

Stop motor before regreasing. Disconnect power; lock out and tag.

Check mark

Outlet plugs or spring-loaded grease relief plugs removed

Check mark

The inlet grease gun fittings and outlet plugs (or spring-loaded reliefs) are located at each end of the motor housing.

Check mark

Drive end outlet plugs located and removed

Check mark

Drain hole free of any hard grease

Check mark

Quantity of grease delivered with each stroke of the lever

Check mark

Recommended volume of the recommended lubricant added

Check mark

Do not expect grease to appear at the outlet, but if it does, discontinue greasing at once.

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Ingersoll Rand

Explore Other Assets