The Ingersoll Rand Air Compressor UPS-40-125BP is a robust industrial compressor designed for high efficiency and reliability. Ideal for various applications, this model ensures optimal air delivery and performance, making it a preferred choice for professionals seeking durable and effective compressed air solutions.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Ingersoll Rand Air Compressor ups-40-125bp
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly / 100 Hourly Air Compressor Maintenance
- Remove and clean package pre–filter, replace if needed.
- Check the cooler(s) for build up of foreign matter. Clean if necessary by blowing out with air or by pressure washing.
Cleaning Procedure:
1. Stop the machine, electrically isolate and vent all trapped pressure.
2. Remove the top cover to obtain access to the cooler.
3. Clean the cooler.
4. Rebuild in reverse order.
- Check hoses and fittings for leaks – tighten as required.;
1 Yearly / 2000 Hourly Air Compressor Maintenance
- Change the coolant filter.
Procedure:
1. Stop the machine, electrically isolate and vent all trapped pressure.
2. Loosen filter with the correct tool.
3. Remove the filter from the housing.
4. Place the old filter in a sealed bag and dispose of in a safe way.
5. Clean the mating face of the housing taking care to avoid any particles entering the machine.
6. Remove the new Ingersoll Rand replacement filter from its protective package.
7. Apply a small amount of lubricant to the filter seal.
1 Yearly / 2000 Hourly Air Filter Replacement
If the air filter indicator locks into red position before the 2000 hour/1 year change out period:
- Check the condition of filter. Change the air filter if needed. Dusty environments require more frequent replacement.
Note: Indicator should be checked with unit stopped.
Procedure:
1. Stop the machine, electrically isolate and vent all trapped pressure.
2. Unclip the retaining cap and withdraw the old element.
3. Fit the new element.
4. Replace the retaining cap.;
24 Hourly Air Compressor Check
Check the coolant level and replenish if necessary.
Visual check of machine for any leaks.
Visual check of machine for dust build up.
Visual check of machine for unusual noise or vibration.
Report immediately, contact Ingersoll Rand authorized distributor for assistance if in doubt.
When compressor is receiver mounted, drain air receiver of condensate, or check that automatic drain is operating.
Sign off on the 24 Hourly Air Compressor Check
2 Yearly / 8000 Hourly Air Compressor Maintenance
- Change drive belt and gas spring.
Procedure:
1. Stop the machine, electrically isolate and vent all trapped pressure.
2. Remove the side cover from the machine.
3. Fit a 1/2” square drive wrench in the tension cam located above the airend (access from front door). Turn clockwise 1/4 turn to Position II to release gas strut tension on the belts.
4. Using a small screwdriver under the spring clip, ease the ball ends off the spherical studs at the ends of the gas strut.
5. Replace the gas strut and the studs at the same time by removing and replacing the studs then pushing the new gas strut firmly onto the studs until it clicks into place.
6. Turn the tension cam clockwise 1/4 turn to Position III to raise and support the airend. Place a block of wood or similar under the separator tank for support.
7. Replace the belts from the left side of the machine.
Access the parts list for your equipment in MaintainX.
Decal, Aircare
22064562
Decal, Condensate Drain
22181663
Decal, Coolant Drain
93166460
Decal, Dual Voltage
32343501
Decal, Facia – Electro–Pneumatic
81295883
Decal, Aircare
22064562
Decal, Condensate Drain
22181663
Decal, Coolant Drain
93166460
Decal, Dual Voltage
32343501
Decal, Facia – Electro–Pneumatic
81295883
Decal, Aircare
22064562
Decal, Condensate Drain
22181663
Decal, Coolant Drain
93166460
Decal, Dual Voltage
32343501
Decal, Facia – Electro–Pneumatic
81295883
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX