MaintainX Asset Hub logo
EnterprisePricing
Graco

Graco Pump Package P36LSS

Need answers fast?
Explore the manual using AI.

Graco Pump Package P36LSS
Graco Pump Package P36LSS

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Graco Pump Package P36LSS

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Graco Pump Package P36LSS

Graco Pump Package P36LSS

Create an account to install this asset package.

Maintenance Plans for Graco Pump Package Model P36LSS

Integrate maintenance plans directly into your work orders in MaintainX.

Initial 1 Week Torque Wet Cup Check

Check mark

Pressure Relief Procedure

Check mark

Lock the gun/valve trigger

Check mark

Unlock the gun/valve trigger

Check mark

Hold a metal part of the gun/valve firmly to the side of a grounded metal pail, and trigger the gun/valve to relieve pressure

Check mark

Lock the gun/valve trigger

Check mark

Open the fluid line drain valve and the pump bleed valve (P). Have a container ready to catch the drainage

Check mark

Leave the pump bleed valve open until ready to spray again

Check mark

Do you suspect that the spray tip/nozzle or hose is completely clogged, or that pressure has not been fully relieved?

Check mark

Integrated Air Controls

Run this procedureArrow right

Pump Package Adjustment

Check mark

Warning: Safety Precautions

Check mark

Keep hands and fingers away from the priming piston during operation and whenever the pump is charged with air.

Check mark

Follow the Pressure Relief Procedure on page 11 before checking, clearing, or cleaning the priming piston.

Check mark

Pump Priming and Adjustment

Check mark

Supply fluid to the pump, per the requirements of your system.

Check mark

Ensure the pump air regulator is closed.

Check mark

Set the ram down air regulator to about 50 psi (3.5 bar).

Check mark

Set the director valve to DOWN.

Check mark

Reduce the air motor regulator pressure and open the air motor slider valve.

Run this procedureArrow right

Torque Wet Cup Check

Check mark

Pressure Relief Procedure

Check mark

Lock the gun/valve trigger

Check mark

Unlock the gun/valve trigger

Check mark

Hold a metal part of the gun/valve firmly to the side of a grounded metal pail, and trigger the gun/valve to relieve pressure

Check mark

Lock the gun/valve trigger

Check mark

Open the fluid line drain valve and the pump bleed valve (P)

Check mark

Leave the pump bleed valve open until ready to spray again

Check mark

Is the spray tip/nozzle or hose completely clogged?

Check mark

If clogged, very slowly loosen the tip guard retaining nut, nozzle, or hose end coupling to relieve pressure gradually, then loosen completely and clear the tip/nozzle or hose

Run this procedureArrow right

Pump Package Maintenance

Check mark

Pressure Relief Procedure

Check mark

Lock the gun/valve trigger.

Check mark

Unlock the gun/valve trigger.

Check mark

Hold a metal part of the gun/valve firmly to the side of a grounded metal pail, and trigger the gun/valve to relieve pressure.

Check mark

Lock the gun/valve trigger.

Check mark

Open the fluid line drain valve and the pump bleed valve (P). Have a container ready to catch the drainage.

Check mark

Leave the pump bleed valve open until ready to spray again.

Check mark

Is the spray tip/nozzle or hose completely clogged, or pressure not fully relieved?

Check mark

If clogged, very slowly loosen the tip guard retaining nut, nozzle, or hose end coupling and relieve pressure gradually, then loosen completely. Clear the tip/nozzle or hose.

Run this procedureArrow right

Parts for Graco Pump Package P36LSS

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Washer, Lock, Spring

108098

Nut, Mach, Hex

106166

Plug, Pipe, Round

120588

Rod, Tie

257360

Adapter, Rod

15H392

Washer, Lock, Spring

108098

Nut, Mach, Hex

106166

Plug, Pipe, Round

120588

Rod, Tie

257360

Adapter, Rod

15H392

Washer, Lock, Spring

108098

Nut, Mach, Hex

106166

Plug, Pipe, Round

120588

Rod, Tie

257360

Adapter, Rod

15H392

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Graco

Explore Other Assets