Geovent Geofilter GFB2 12-4
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Geofilter Maintenance
Supply of compressed air is clean and dry
Pressure loss over the filter
Filter cartridges changed if pressure loss exceeds 2.000Pa
Filter’s clean side checked for dust particles
Filter cartridges changed in the event of leakage
Sign off on the Geofilter Maintenance
Collection Bucket Maintenance
Empty the bucket when it reaches around 2/3 capacity, otherwise it may place further strain on the filter cartridges. Following this, dispose of the bucket’s content responsibly according to existing regulations.
1. Pull the handle up
2. Pull/roll out bucket and empty
3. Roll bucket in and push handle down while holding bucket in place.
Opening and closing the door
1. Loosen the bolts, turn the latch 90° to the left.
2. The door opens (the filter can be replaced)
3. After filter change, close the door again.
4. Turn the latch 90° to the right, while holding the door in place.
4 Yearly / 4000 Hourly Filter Cartridge Replacement
The filter cartridges should be changed after about 4.000 – 8.000 hours of operation or after a maximum of 4 years. This depends partially on the strain on the filter, and partially on what its use has been.
Procedure:
1. Before opening the door of the filter, it is important that the service technician takes the necessary personal safety precautions such as wearing a respirator and gloves that meet the Working Environment Authority’s rules for working with contaminated dust.
2. All power must be disconnected and unable to be activated during servicing.
3. Loosen all screws holding the filter cartridges in place.
4. Turn the filter to remove it.
5. Place the contaminated filter in a plastic bag and dispose it according to rules for hazardous waste.
6. Mount the clean filter cartridge by repeating the above steps in reverse order.
7. Check the filter for functionality and leakage before use.
Geofilter Cleaning
Warning: Do not clean the product during operation. Turn the product off before cleaning.
Product turned off before cleaning?
The filter self-cleans automatically as a compressed air pulse is sent down through the filter cartridges, causing the particles on the textile of the filter to be blown off and collected in the bucket below.
Warning: Do not open the doors during operation to avoid injury.
Doors remained closed during operation?
Cleaning of the inside of the product is not recommended.
When the doors of the product are opened, you must wear protection gloves, eye protection and a suit covering your body.
Wore protection gloves, eye protection and a suit covering your body when doors were opened?
Sign off on the Geofilter Cleaning
Access the parts list for your equipment in MaintainX.
Timer Control Panel GFB2
92-214
Differential Pressure Control Panel GFB2
92-214B
Solenoid Valve 24V
93-VNP-208
FT/11 - 99.9% at 0.3µm (grinding dust / All-Round)
15-480FL
FT/11 - 99.9% at 0.3µm ALUTEC (All-Round)
15-480AFL
Timer Control Panel GFB2
92-214
Differential Pressure Control Panel GFB2
92-214B
Solenoid Valve 24V
93-VNP-208
FT/11 - 99.9% at 0.3µm (grinding dust / All-Round)
15-480FL
FT/11 - 99.9% at 0.3µm ALUTEC (All-Round)
15-480AFL
Timer Control Panel GFB2
92-214
Differential Pressure Control Panel GFB2
92-214B
Solenoid Valve 24V
93-VNP-208
FT/11 - 99.9% at 0.3µm (grinding dust / All-Round)
15-480FL
FT/11 - 99.9% at 0.3µm ALUTEC (All-Round)
15-480AFL
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX