Fresenius Kabi Sterile Tube Connection System CompoDock
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Electrodes Check Tube Holders
6.4 Cleaning the Tube Guides
Check the tube holders on either side every day
If contaminated, the tube holders must be cleaned
Warning: Contaminations support incorrect positioning of the tubes. This may result in reduced dock quality and/or to repeated improper docks.
1 Daily Electrodes Check
6.3 Cleaning the Electrodes
Daily checks
The sealing electrodes must be checked every day. If contaminated, the electrodes must be cleaned, because contaminations may adversely affect the sealing process.
Are the electrodes contaminated?
To facilitate cleaning of the sealing electrodes, simultaneously press the Start and Stop keys. The tube clamps move to the 'cleaning position'. Press the Start key again to open and close the electrodes.
Did you press the Start and Stop keys simultaneously?
Did you press the Start key again to open and close the electrodes?
Use a cotton applicator dampened with disinfectant (Freka®-NOL) for cleaning. Dry the electrodes after having cleaned them.
Did you clean the electrodes with a cotton applicator dampened with disinfectant (Freka®-NOL)?
Surface Cleaning
6 Cleaning / Disinfection
Caution
For cleaning and disinfecting the surfaces, turn off the device and disconnect it from power supply.
6.1 Surface Cleaning
Caution
When cleaning the CompoDock, ensure that fluid is prevented from entering inside.
Prevent spraying inside the device or onto its surfaces.
Clean the surfaces of the device with a moist cloth and a neutral cleaning agent.
If fluid (blood, blood components or cleaning agent) has entered into the device, turn off the device and notify the service technician.
1 Yearly Tube Connection System Maintenance
Warning: This maintenance check requires trained personnel with PPE!
Service message on the display?
If service message is displayed, initiate maintenance measures
Tube clamps cleaned
Device fully operational after cleaning
Sign off on the tube connection system maintenance
Access the parts list for your equipment in MaintainX.
Compodock Counter 500
902 870 1
Compodock Counter 1000
902 869 1
Compodock Counter 2500
902 868 1
Side Table, Right
M61 110 1
Side Table, Left
M61 117 1
Compodock Counter 500
902 870 1
Compodock Counter 1000
902 869 1
Compodock Counter 2500
902 868 1
Side Table, Right
M61 110 1
Side Table, Left
M61 117 1
Compodock Counter 500
902 870 1
Compodock Counter 1000
902 869 1
Compodock Counter 2500
902 868 1
Side Table, Right
M61 110 1
Side Table, Left
M61 117 1
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX