Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more
Danfoss Condensing Unit OP-MPXM108MLP00E
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Year Condensing Unit Check
WARNING! Always switch off the unit at main switch before opening the fan door(s). Internal pressure and surface temperature are dangerous and may cause permanent injury. Maintenance operators and installers require appropriate skills and tools. Tubing temperature may exceed 100°C and can cause severe burns.
Ensure that periodic service inspections to ensure system reliability and as required by local regulations are performed.
Check the condenser for clogging.
Clean the condenser if necessary.
Remove surface dirt, leaves, fibers, etc. with a vacuum cleaner, equipped with a brush or other soft attachment.
Blow compressed air through the coil from the inside out, and brush with a soft bristle.
Turn the fan blade in a safe position, to avoid that the door hits the fan.
If the refrigerant system has been opened, flush the system with dry air or nitrogen to remove moisture.
Install a new filter drier if the refrigerant system has been opened.
Condensing Unit Periodic Maintenance
WARNING: Always switch off the unit at main switch before opening the fan door(s). Internal pressure and surface temperature are dangerous and may cause permanent injury. Maintenance operators and installers require appropriate skills and tools. Tubing temperature may exceed 100°C and can cause severe burns.
Ensure that periodic service inspections to ensure system reliability and as required by local regulations are performed.
Safety devices are operational and properly set.
The system is leak tight.
Compressor current draw.
The system is operating in a way consistent with previous maintenance records and ambient conditions.
All electrical connections are still adequately fastened.
The unit is clean and there is no rust and oxidation on the unit components, tubes and electrical connections.
Sign off on the condensing unit periodic maintenance
Access the parts list for your equipment in MaintainX.
Compressor
MLZ048T4
Oil
215PZ-POE46
Compressor Single Pack
121L8651
Condenser
118U5219
Discharge Pressure Sensor
118U4021
Compressor
MLZ048T4
Oil
215PZ-POE46
Compressor Single Pack
121L8651
Condenser
118U5219
Discharge Pressure Sensor
118U4021
Compressor
MLZ048T4
Oil
215PZ-POE46
Compressor Single Pack
121L8651
Condenser
118U5219
Discharge Pressure Sensor
118U4021
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX