The Daikin Outdoor Heat Pump RXS25G2V1B9 is a high-efficiency HVAC solution designed for residential and commercial applications. Known for its reliability and performance, this model provides optimal heating and cooling, ensuring comfort in various environments. Ideal for energy-conscious users, it combines advanced technology with ease of maintenance.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Outdoor Heat Pump RXS25G2V1B9
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Compressor Removal
Warning: Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Remove the 2 nuts of the compressor.
Warning: Be careful not to get yourself burnt with pipes and other parts that are heated by the gas brazing machine.
Warning: If the refrigerant gas leaks during work, ventilate the room. (If the refrigerant gas is exposed to flames, toxic gas may be generated.)
Warning: Since it may happen that the refrigerant oil in the compressor catches fire, prepare wet cloth so as to extinguish fire immediately.
Caution: From the viewpoint of global environment protection, do not discharge the refrigerant gas in the atmosphere. Make sure to collect all the refrigerant gas.
Restore the piping by nonoxidation brazing.
It is required to prevent the carbonization of the oil inside the four way valve and the deterioration of the gaskets affected by heat. (Keep below 120°C.) For the sake of this, wrap the four way valve with wet cloth and provide water so that the cloth does not dry.
Disconnect the brazed part where is easy to disconnect and restore.
Electrical Box Removal
Warning: Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Preparation: Remove the panels and disconnect the connector for the fan motor according to the “Removal of Outer Panels / Fan Motor”.
Disconnect the connector for the overload protector [S40]
Disconnect the connector for the four way valve coil [S80]
Disconnect the 2 connectors for the reactor
Disconnect the relay connector for the compressor
Disconnect the connector for the electronic expansion valve coil [S20]
Cut the clamp
Pull out the outdoor heat exchanger thermistor. Be careful not to lose the clip for the thermistor.
Electronic Expansion Valve Check
EV connector correctly connected to the PCB
EV generates latching sound when power is turned off and on again
If EV does not generate latching sound, proceed to next step
Continuity confirmed when connector is disconnected and tested with a tester
Check continuity between the following pins
If there is no continuity between the pins, the EV coil is faulty
If continuity is confirmed, the outdoor unit PCB is faulty
Note: The latching sound varies depending on the valve type
Sign off on the electronic expansion valve check
Fan Motor Connector Output Check
Check the connection of connector
Check the motor power supply voltage output (pins 4 - 7)
Check the motor control voltage (pins 4 - 3)
Check the rotation command voltage (pins 4 - 2)
Check the rotation pulse (pins 4 - 1)
Sign off on the fan motor connector output check
Four Way Valve Removal
Warning: Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Pull out the electronic expansion valve coil.
Remove the terminal cover.
Disconnect the lead wires of the compressor.
Remove the screw and remove the four way valve coil.
Warning: Be careful not to get yourself burnt with the pipes and other parts that are heated by the gas brazing machine.
Warning: If the refrigerant gas leaks during work, ventilate the room. (If the refrigerant gas is exposed to flames, toxic gas may be generated.)
Caution: From the viewpoint of global environment protection, do not discharge the refrigerant gas in the atmosphere. Make sure to collect all the refrigerant gas.
Cautions for restoration
Access the parts list for your equipment in MaintainX.
Inverter Checker
1225477
Silicon Grease
1172698
Inverter Checker
1225477
Silicon Grease
1172698
Inverter Checker
1225477
Silicon Grease
1172698
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX