Daikin Condensing Unit DX13SSA0363AD
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
3-Phase Scroll Compressor Rotation Check
NOTE: The compressor may run backwards (noisy operation) for 1 or 2 seconds at shutdown. This is normal and does not harm the compressor.
Install gauges and verify that the suction pressure drops while the discharge pressure increases.
Listen for normal compressor sound levels. Reverse rotation results in elevated or unusual sound levels.
Reverse rotation will result in substantially reduced amp draw from tabulated values.
To correct improper rotation, switch any two power supply leads at the outdoor unit contactor.
The 3-phase scroll compressors are direction of rotation sensitive. They will rotate in either direction depending on the phasing of the power. There is no negative impact on durability caused by operating 3-phase compressors in reversed rotation.
The compressor’s internal protector will trip, de-energizing the compressor. Continued operation of 3-phase scroll compressors with the rotation reversed will contribute to compressor failure. All 3-phase scroll compressors should be checked for correct phase rotation.
Sign off on the compressor rotation check
Aluminum Coil Cleaning
This unit is equipped with an aluminum tube evaporator coil.
The safest way to clean the evaporator coil is to simply flush the coil with water. This cleaning practice remains as the recommended cleaning method for both copper tube and aluminum tube residential cooling coils.
An alternate cleaning method is to use one of the products listed in the technical publication TP-109 (shipped in the literature bag with the unit) to clean the coils. The cleaners listed are the only agents deemed safe and approved for use to clean round tube aluminum coils. TP-109 is available on the web site in Partner Link > Service Toolkit.
Did you flush the coil with water?
Select the cleaning method used
NOTE: Ensure coils are rinsed well after use of any chemical cleaners.
Did you rinse the coils well after cleaning?
Sign off on the coil cleaning
Capacitance Check
WARNING: Discharge capacitor through a 20 to 30 OHM resistor before handling.
NOTE: You can do this test with a multi-meter if you have a Capacitance meter on your multi-meter.
Capacitor removed from the circuit
Multi-meter set to 'Capacitance'
Capacitor terminals connected to the multi-meter leads
Enter the reading from the multi-meter
Enter the actual value of the capacitor (i.e. the printed value on the capacitor)
Is the reading near to the actual value of the capacitor?
If the reading is significantly lower or none at all, is the capacitor replaced?
Capacitor Check
CAPACITOR, RUN
A run capacitor is wired across the auxiliary and main windings of a single phase permanent split capacitor motor. The capacitors primary function is to reduce the line current while greatly improving the torque characteristics of a motor.
This is accomplished by using the 90° phase relationship between the capacitor current and voltage in conjunction with the motor windings, so that the motor will give two phase operation when connected to a single phase circuit. The capacitor also reduces the line current to the motor by improving the power factor.
The line side of this capacitor is marked with "COM" and is wired to the line side of the circuit.
CAPACITOR, START
SCROLL COMPRESSOR MODELS
In most cases hard start components are not required on Scroll compressor equipped units due to a non-replaceable check valve located in the discharge line of the compressor.
However, in installations that encounter low lock rotor voltage, a hard start kit can improve starting characteristics and reduce light dimming within the home. Only hard start kits approved by Amana® brand or Copeland should be used. "Kick Start" and/or "Super Boost" kits are not approved start assist devices.
The discharge check valve closes off high side pressure to the compressor after shut down allowing equalization through the scroll flanks. Equalization requires only about 1/2 second.
Compressor Check
WARNING: Hermetic compressor electrical terminal venting can be dangerous.
Ensure all open flame, electrical power, and other heat sources are extinguished or turned off prior to servicing a system.
Compressor terminal PROTECTIVE COVER and gasket properly in place and secured
Proper evacuation of a hermetic system at the time of manufacture and during servicing
Upload a photo of the compressor terminal
Sign off on the compressor check
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX