MaintainX Asset Hub logo
EnterprisePricing
Daikin

Daikin Package Gas Unit DP13GM3007041A

Need answers fast?
Explore the manual using AI.

Daikin Package Gas Unit DP13GM3007041A
Daikin Package Gas Unit DP13GM3007041A

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Package Gas Unit DP13GM3007041A

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Package Gas Unit DP13GM3007041A

Daikin Package Gas Unit DP13GM3007041A

Create an account to install this asset package.

Maintenance Plans for Daikin Package Gas Unit Model DP13GM3007041A

Integrate maintenance plans directly into your work orders in MaintainX.

Aluminum Indoor Coil Cleaning

Check mark

WARNING! HIGH VOLTAGE! Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death.

Check mark

IMPORTANT NOTE: Never operate unit without a filter installed as dust and lint will build up on internal parts resulting in loss of efficiency, equipment damage and possible fire.

Check mark

Power disconnected?

Check mark

Filter installed?

Check mark

This unit is equipped with an aluminum tube evaporator coil. The safest way to clean the evaporator coil is to simply flush the coil with water.

Check mark

Flushed the coil with water?

Check mark

Sign off on the coil cleaning

Run this procedureArrow right

6 Monthly Package Inspection

Check mark

WARNING!

Check mark

HIGH VOLTAGE!

Check mark

Disconnect all power before servicing or installing this unit. Multiple power sources may be present.

Check mark

Failure to do so may cause property damage, personal injury or death.

Check mark

IMPORTANT NOTE: Never operate unit without a filter installed as dust and lint will build up on internal parts resulting in loss of efficiency, equipment damage and possible fire.

Check mark

The coils should be free of debris so adequate airflow is achieved.

Check mark

The return and supply registers should be free of any obstructions.

Check mark

The filters should be cleaned or replaced.

Check mark

Your package unit should be inspected by a qualified installer, or service agency at least twice every year.

Run this procedureArrow right

2 Monthly Filters Replacement

Check mark

WARNING! HIGH VOLTAGE! Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death.

Check mark

IMPORTANT NOTE: Never operate unit without a filter installed as dust and lint will build up on internal parts resulting in loss of efficiency, equipment damage and possible fire.

Check mark

An indoor air filter must be used with your comfort system. A properly maintained filter will keep the indoor coil of your comfort system clean. A dirty coil could cause poor operation and/or severe equipment damage.

Check mark

Check your return filter(s) at least once every two months. When they are dirty, replace or clean as required.

Check mark

Type of filter

Check mark

NOTE: Reusable type filters should be washed with warm water, dried completely and sprayed with an adhesive according to the manufacturers recommendations.

Check mark

Filters should be cleaned (permanent) or replaced (disposable) every two months or as required.

Check mark

When replacing a filter, it must be replaced with a filter of the same type and size and always make certain the air flow arrows on the filter point in the proper direction.

Check mark

Sign off on the filter replacement

Run this procedureArrow right

Parts for Daikin Package Gas Unit DP13GM3007041A

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

3 Ton Concentric Duct Kit

CDK36

3 Ton Flush Mount Concentric Duct Kit w/ Filter

CDK36515

3 Ton Step Down Concentric Duct Kit

CDK36530

3 Ton Step Down Concentric Duct Kit w/ Filter

CDK36535

4 - 6 Ton Concentric Duct Kit

CDK4872

3 Ton Concentric Duct Kit

CDK36

3 Ton Flush Mount Concentric Duct Kit w/ Filter

CDK36515

3 Ton Step Down Concentric Duct Kit

CDK36530

3 Ton Step Down Concentric Duct Kit w/ Filter

CDK36535

4 - 6 Ton Concentric Duct Kit

CDK4872

3 Ton Concentric Duct Kit

CDK36

3 Ton Flush Mount Concentric Duct Kit w/ Filter

CDK36515

3 Ton Step Down Concentric Duct Kit

CDK36530

3 Ton Step Down Concentric Duct Kit w/ Filter

CDK36535

4 - 6 Ton Concentric Duct Kit

CDK4872

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets