MaintainX Logo
EnterprisePricing
Daikin

Daikin Indoor Unit Wall Mounted Type FTXS20CAVMB

Need answers fast?
Explore the manual using AI.

Daikin Indoor Unit Wall Mounted Type FTXS20CAVMB
Daikin Indoor Unit Wall Mounted Type FTXS20CAVMB

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Indoor Unit Wall Mounted Type FTXS20CAVMB

Daikin Indoor Unit Wall Mounted Type FTXS20CAVMB

Create an account to install this asset package.

Maintenance Plans for Daikin Indoor Unit Wall Mounted Type Model FTXS20CAVMB

Integrate maintenance plans directly into your work orders in MaintainX.

Power Supply Waveforms Check

Check mark

Check No.10: Power Supply Waveforms Check

Check mark

Measure the power supply waveform between pins 1 and 3 on the terminal board

Check mark

Check the waveform disturbance

Check mark

Check to see if the power supply waveform is a sine wave (Fig.1)

Check mark

Check to see if there is waveform disturbance near the zero cross (sections circled in Fig.2)

Check mark

Upload a photo of the waveform

Check mark

Sign off on the power supply waveforms check

Run this procedureArrow right

Capacitor Voltage Check

Check mark

Warning: Check the main circuit for short-circuit before proceeding

Check mark

Main circuit checked for short-circuit

Check mark

Warning: Be careful never to touch any live parts

Check mark

Capacitor voltage reading

Check mark

Sign off on the capacitor voltage check

Run this procedureArrow right

Elecrical Box Removal

Check mark

Warning: Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Disconnect the connecting wires

Check mark

Fasten the wires on the terminal board with screws

Check mark

Disconnect the each harnesses

Check mark

Detach the fixing tape for the electrical box (cover)

Check mark

Undo the 4 hooks at the mark of the drip proof cover

Check mark

Lift the cover up to remove

Check mark

Disconnect the connector for fan motor [S70] from the PCB

Check mark

Disconnect the connectors for electronic expansion valve coil

Run this procedureArrow right

Compressor Removal

Check mark

Warning: Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Warning: Since it may happen that refrigeration oil in the compressor will catch fire, prepare wet cloth so as to extinguish fire immediately.

Check mark

Warning: Ventilate when refrigerant leaks during the work. (If refrigerant contacts fire, it will cause to arise toxic gas.)

Check mark

Caution: Be careful not to get yourself burnt with the pipes and other parts that are heated by the gas welding rod.

Check mark

Remove the terminal cover.

Check mark

Disconnect the flagshaped terminals.

Check mark

Detach the compressor lead wire.

Check mark

Detach the overload protector.

Check mark

Remove the 2 sheets of putty.

Run this procedureArrow right

Propeller Fan / Fan Motor Removal

Check mark

Warning: Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Remove the fan motor fixing plate.

Check mark

Remove the outer panels and plates.

Check mark

Remove the electrical box.

Check mark

Take out the fan motor fixing plate toward yourself.

Check mark

When assembling, fit the lower hooks.

Check mark

Loosen the washer fitted nut to remove the propeller fan.

Check mark

When assembling, align mark of the propeller fan with D-cut section of the motor shaft.

Check mark

When assembling, make sure ! mark of the fan motor goes up.

Run this procedureArrow right

Parts for Daikin Indoor Unit Wall Mounted Type FTXS20CAVMB

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Titanium Apatite Photocatalytic Air-Purifying Filter. (Without Frame) 1 Set

KAF970A46

Air Purifying Filter With Photocatalytic Deodorizing Function. (With Frame) 1 Set

KAF918A43

Air Purifying Filter With Photocatalytic Deodorizing Function. (Without Frame) 1 Set

KAF918A44

Titanium Apatite Photocatalystic Air-Purifying Filter (Without Frame) 1 Set

KAF952B42

Titanium Apatite Photocatalytic Air-Purifying Filter. (With Frame) 1 Set

KAF952B41

Titanium Apatite Photocatalytic Air-Purifying Filter. (Without Frame) 1 Set

KAF970A46

Air Purifying Filter With Photocatalytic Deodorizing Function. (With Frame) 1 Set

KAF918A43

Air Purifying Filter With Photocatalytic Deodorizing Function. (Without Frame) 1 Set

KAF918A44

Titanium Apatite Photocatalystic Air-Purifying Filter (Without Frame) 1 Set

KAF952B42

Titanium Apatite Photocatalytic Air-Purifying Filter. (With Frame) 1 Set

KAF952B41

Titanium Apatite Photocatalytic Air-Purifying Filter. (Without Frame) 1 Set

KAF970A46

Air Purifying Filter With Photocatalytic Deodorizing Function. (With Frame) 1 Set

KAF918A43

Air Purifying Filter With Photocatalytic Deodorizing Function. (Without Frame) 1 Set

KAF918A44

Titanium Apatite Photocatalystic Air-Purifying Filter (Without Frame) 1 Set

KAF952B42

Titanium Apatite Photocatalytic Air-Purifying Filter. (With Frame) 1 Set

KAF952B41

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets