

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Indoor Unit Wall Mounted Type FTXS20CAVMB
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Power Supply Waveforms Check
Check No.10: Power Supply Waveforms Check
Measure the power supply waveform between pins 1 and 3 on the terminal board
Check the waveform disturbance
Check to see if the power supply waveform is a sine wave (Fig.1)
Check to see if there is waveform disturbance near the zero cross (sections circled in Fig.2)
Upload a photo of the waveform
Sign off on the power supply waveforms check
Capacitor Voltage Check
Warning: Check the main circuit for short-circuit before proceeding
Main circuit checked for short-circuit
Warning: Be careful never to touch any live parts
Capacitor voltage reading
Sign off on the capacitor voltage check
Elecrical Box Removal
Warning: Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Disconnect the connecting wires
Fasten the wires on the terminal board with screws
Disconnect the each harnesses
Detach the fixing tape for the electrical box (cover)
Undo the 4 hooks at the mark of the drip proof cover
Lift the cover up to remove
Disconnect the connector for fan motor [S70] from the PCB
Disconnect the connectors for electronic expansion valve coil
Compressor Removal
Warning: Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Warning: Since it may happen that refrigeration oil in the compressor will catch fire, prepare wet cloth so as to extinguish fire immediately.
Warning: Ventilate when refrigerant leaks during the work. (If refrigerant contacts fire, it will cause to arise toxic gas.)
Caution: Be careful not to get yourself burnt with the pipes and other parts that are heated by the gas welding rod.
Remove the terminal cover.
Disconnect the flagshaped terminals.
Detach the compressor lead wire.
Detach the overload protector.
Remove the 2 sheets of putty.
Propeller Fan / Fan Motor Removal
Warning: Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Remove the fan motor fixing plate.
Remove the outer panels and plates.
Remove the electrical box.
Take out the fan motor fixing plate toward yourself.
When assembling, fit the lower hooks.
Loosen the washer fitted nut to remove the propeller fan.
When assembling, align mark of the propeller fan with D-cut section of the motor shaft.
When assembling, make sure ! mark of the fan motor goes up.
Access the parts list for your equipment in MaintainX.
Titanium Apatite Photocatalytic Air-Purifying Filter. (Without Frame) 1 Set
KAF970A46
Air Purifying Filter With Photocatalytic Deodorizing Function. (With Frame) 1 Set
KAF918A43
Air Purifying Filter With Photocatalytic Deodorizing Function. (Without Frame) 1 Set
KAF918A44
Titanium Apatite Photocatalystic Air-Purifying Filter (Without Frame) 1 Set
KAF952B42
Titanium Apatite Photocatalytic Air-Purifying Filter. (With Frame) 1 Set
KAF952B41
Titanium Apatite Photocatalytic Air-Purifying Filter. (Without Frame) 1 Set
KAF970A46
Air Purifying Filter With Photocatalytic Deodorizing Function. (With Frame) 1 Set
KAF918A43
Air Purifying Filter With Photocatalytic Deodorizing Function. (Without Frame) 1 Set
KAF918A44
Titanium Apatite Photocatalystic Air-Purifying Filter (Without Frame) 1 Set
KAF952B42
Titanium Apatite Photocatalytic Air-Purifying Filter. (With Frame) 1 Set
KAF952B41
Titanium Apatite Photocatalytic Air-Purifying Filter. (Without Frame) 1 Set
KAF970A46
Air Purifying Filter With Photocatalytic Deodorizing Function. (With Frame) 1 Set
KAF918A43
Air Purifying Filter With Photocatalytic Deodorizing Function. (Without Frame) 1 Set
KAF918A44
Titanium Apatite Photocatalystic Air-Purifying Filter (Without Frame) 1 Set
KAF952B42
Titanium Apatite Photocatalytic Air-Purifying Filter. (With Frame) 1 Set
KAF952B41
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













