Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Air Handling Unit OAH030GHAM
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
48 Hours Air Handling Unit Check
Disconnect and lock electrical power source
Check tightness of all bearing, wheel, and sheave setscrews (or capscrews). Refer to Table 28 on page 42
Recheck belt tension and adjust if necessary. Belts that are tensioned sufficiently to slip one to two seconds at startup perform satisfactorily, extending life and reducing vibration
If re-tensioning is necessary, be certain to retain sheave alignment
Fan Drive Sheaves Maintenance
Fan Drive
WARNING
Before servicing lock out and tag out all power to the unit
Fans or belts cause severe personal injury or death
WARNING
Do not open the hinged access door and screw-fastened access panels while the unit is operating
Moving parts and strong suction forces can cause severe personal injury or death
Upon completion of the air balance, replace the variable pitched motor sheave with a properly sized, fixed sheave
A matching fixed sheave provides longer belt and bearing life and minimizes vibration
Water Coils Winterizing
WARNING: Mold can cause personal injury. Clean drain pan regularly so mold does not develop.
Coils can freeze due to air stratification or failure of outdoor air dampers and/or preheat controls.
Do not depend on routine draining of water cooling coils for winter shutdown as insurance against freeze-up. Severe coil damage can result.
Drain all coils as thoroughly as possible
Fill each coil independently with an antifreeze solution using a small circulating pump and again thoroughly drain.
Check freezing point of antifreeze before proceeding to next coil.
Due to a small amount of water always remaining in each coil, there is a diluting effect. The small amount of antifreeze solution remaining in the coil must always be concentrated enough to prevent freeze-up.
NOTE: Carefully read instructions for mixing antifreeze solution used. Some products have a higher freezing point in their natural state when mixed with water.
Daikin Applied is not responsible for the freezing of coils.
Air Handling Unit Components Replacement
Removing and Replacing Components
WARNING
Before removing component, lock out and tag out all power to the unit
Fans and belts can cause severe personal injury or death
See page 12 for instructions on removing panels and opening fan access doors to remove or replace components
Removing the Fan Section
The fan shaft, motor, and any drive components can be removed and replaced through the access door opening
If required, the side panel can be removed for additional access
If fan replacement is required, the entire fan assembly can be pulled out the side of the cabinet for housed fan assemblies
Front Load Filter Change
Warning: Ensure the unit is turned off before starting the procedure
Filters removed from inside the unit
Wire clips rotated
Prefilter and final filter released
Clean filters installed
Filters fully seated in the frame
Sign off on the filter change
Access the parts list for your equipment in MaintainX.
High Voltage Harness, 30 Foot Long, One Required Per Fan
910232406
Block-Off Plate, Fan Size 355, All kW
910198700
Block-Off Plate, Fan Size 450, All kW
910198701
Block-Off Plate, Fan Size 560, All kW
910311272
Block-Off Plate, Fan Size 630, 5.9 kW; 6.3 kW
910311272
High Voltage Harness, 30 Foot Long, One Required Per Fan
910232406
Block-Off Plate, Fan Size 355, All kW
910198700
Block-Off Plate, Fan Size 450, All kW
910198701
Block-Off Plate, Fan Size 560, All kW
910311272
Block-Off Plate, Fan Size 630, 5.9 kW; 6.3 kW
910311272
High Voltage Harness, 30 Foot Long, One Required Per Fan
910232406
Block-Off Plate, Fan Size 355, All kW
910198700
Block-Off Plate, Fan Size 450, All kW
910198701
Block-Off Plate, Fan Size 560, All kW
910311272
Block-Off Plate, Fan Size 630, 5.9 kW; 6.3 kW
910311272
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX