MaintainX Logo
EnterprisePricing
Daikin

Daikin Daikin Air Conditioner FTXV80WVMA FTXV80WVMA

Need answers fast?
Explore the manual using AI.

Daikin Daikin Air Conditioner FTXV80WVMA FTXV80WVMA
Daikin Daikin Air Conditioner FTXV80WVMA FTXV80WVMA

The Daikin Air Conditioner FTXV80WVMA is a high-efficiency cooling solution designed for residential and commercial applications. Known for its reliability and advanced technology, this model ensures optimal comfort and energy savings throughout its lifecycle.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Daikin Air Conditioner FTXV80WVMA FTXV80WVMA

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Daikin Air Conditioner FTXV80WVMA FTXV80WVMA

Daikin Daikin Air Conditioner FTXV80WVMA FTXV80WVMA

Create an account to install this asset package.

Maintenance Plans for Daikin Daikin Air Conditioner FTXV80WVMA Model FTXV80WVMA

Integrate maintenance plans directly into your work orders in MaintainX.

Air Conditioner Cleaning

Check mark

CAUTION: Before cleaning, be sure to stop the operation and turn off the circuit breaker

Check mark

Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury

Check mark

For cleaning, do not use the materials as follows: Hot water above 40°C, Volatile liquid such as benzene, petrol and thinner, Polishing compound, Rough materials such as a scrubbing brush

Check mark

Clean Indoor unit, Outdoor unit and Remote controller if bothered by dirt

Check mark

Wipe them with soft cloth

Check mark

Prior to a long period of non-use:

Check mark

Operate the FAN mode for several hours on a fine day to dry out the inside

Check mark

Press MODE and select “FAN”

Check mark

Press ON/OFF and start the operation

Run this procedureArrow right

1 Yearly Battery Replacement

Check mark

Warning: To avoid possible injury or damage from battery leakage or rupturing, remove the batteries when not using the product for long periods of time

Check mark

Both batteries replaced at the same time with new size AAA.LR03 (alkaline) batteries

Check mark

Is the LCD blinking as an alert that the batteries need replacing?

Check mark

Note: The batteries supplied with the remote controller are for initial operation. The batteries may run out in less than 1 year

Check mark

Note: The usable period of the batteries may be short depending on the manufactured date of the air conditioner

Check mark

Sign off on the battery replacement

Run this procedureArrow right

6 Monthly Air-Purifying Filter Maintenance

Check mark

Warning: The method of cleaning and replacement of the filters may differ depending on the model. Refer to the label attached to the separately sold filters themselves

Check mark

Open the front panel and pull out the air filters

Check mark

Check that the filters are inserted securely under the tabs

Check mark

Remove the filters from the tabs

Check mark

Vacuum dust, and soak in lukewarm water or water for about 10 to 15 minutes if very dirty

Check mark

After washing, shake off remaining water and let them dry in the shade

Check mark

Do not wiring out the filter when removing water from it

Check mark

Do not wash the filters as this will reduce their efficiency

Check mark

Remove each filter from the front grille by detaching them from the 6 tabs and then install the new filters

Run this procedureArrow right

Front Panel Cleaning

Check mark

CAUTION: Before cleaning, be sure to stop the operation and turn off the circuit breaker

Check mark

CAUTION: Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury

Check mark

Front panel cleaned

Check mark

Wiped with a soft damp cloth

Check mark

Neutral detergent used

Check mark

For cleaning, do not use any of the following: Water hotter than 40°C, Volatile liquid such as benzene, petrol and thinner, Polishing compounds, Rough materials such as a scrubbing brush

Check mark

Sign off on the front panel cleaning

Run this procedureArrow right

2 Weekly Air Filter Cleaning

Check mark

Warning: Ensure the air conditioner is turned off before starting the cleaning process

Check mark

Open the front panel

Check mark

Pull out the air filters

Check mark

Choose the cleaning method

Check mark

Reattach the filters

Check mark

Close the front panel securely

Check mark

Sign off on the air filter cleaning

Run this procedureArrow right

Parts for Daikin Daikin Air Conditioner FTXV80WVMA FTXV80WVMA

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Deodorizing Filter

BAFP094A45

Dust Collection Filter

BAFP046A43

Remote Controller

ARC466A80

Air Quality Filter

BAFP094A47

Dry Batteries

AAA.LR03

Deodorizing Filter

BAFP094A45

Dust Collection Filter

BAFP046A43

Remote Controller

ARC466A80

Air Quality Filter

BAFP094A47

Dry Batteries

AAA.LR03

Deodorizing Filter

BAFP094A45

Dust Collection Filter

BAFP046A43

Remote Controller

ARC466A80

Air Quality Filter

BAFP094A47

Dry Batteries

AAA.LR03

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets