MaintainX Logo
EnterprisePricing
Daikin

Daikin Air Conditioner FTXM25M2V1B

Need answers fast?
Explore the manual using AI.

Daikin Air Conditioner FTXM25M2V1B
Daikin Air Conditioner FTXM25M2V1B

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Air Conditioner FTXM25M2V1B

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Air Conditioner FTXM25M2V1B

Daikin Air Conditioner FTXM25M2V1B

Create an account to install this asset package.

Maintenance Plans for Daikin Air Conditioner Model FTXM25M2V1B

Integrate maintenance plans directly into your work orders in MaintainX.

6 Monthly Air-Purifying Filter Maintenance

Check mark

Warning: This maintenance check requires trained personnel with PPE!

Check mark

Open the front panel and pull out the air filters

Check mark

Take off the titanium apatite photocatalytic air-purifying filters from the tabs

Check mark

Choose the type of service done

Check mark

Cleaning Procedure

Check mark

Vacuum dust, and soak in lukewarm water or water for about 10 to 15 minutes if very dirty

Check mark

After washing, shake off remaining water and let them dry in the shade

Check mark

Replacement Procedure

Check mark

Remove the filter from the tabs and prepare a new one

Run this procedureArrow right

1 Yearly Battery Replacement

Check mark

Warning: Always replace both batteries together using the same type.

Check mark

Old batteries removed?

Check mark

Type of new batteries used

Check mark

New batteries installed?

Check mark

Note: If the remote controller display begins to fade or reception performance degrades within a year, replace the batteries.

Check mark

Sign off on the battery replacement

Run this procedureArrow right

Air Conditioner Maintenance

Check mark

CAUTION: Before cleaning, be sure to stop the operation and turn off the circuit breaker

Check mark

Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury

Check mark

Clean Indoor unit, Outdoor unit and Remote controller if bothered by dirt

Check mark

Wipe them with soft cloth

Check mark

For cleaning, do not use the materials as follows: Hot water above 40°C, Volatile liquid such as benzene, petrol and thinner, Polishing compound, Rough materials such as a scrubbing brush

Check mark

Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded

Check mark

Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit

Check mark

Check that the drain comes smoothly out of the drain hose during COOL or DRY operation

Check mark

If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the service shop if this is the case

Run this procedureArrow right

Front Panel Cleaning

Check mark

CAUTION: Before cleaning, be sure to stop the operation and turn off the circuit breaker

Check mark

CAUTION: Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury

Check mark

CAUTION: When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully

Check mark

CAUTION: When removing or attaching the front panel, support the panel securely with hand to prevent it from falling

Check mark

CAUTION: After cleaning, make sure that the front panel is securely fixed

Check mark

Is the front panel dirty?

Check mark

If the front panel is dirty, proceed with the following steps

Check mark

How to open the front panel: Hold both ends of the front panel, and then pull to open it

Check mark

How to close the front panel: Press the front panel at both sides to close it

Run this procedureArrow right

2 Weekly Air Filter Cleaning

Check mark

Warning: Do not touch the aluminium fins by bare hand at the time of dismounting or mounting the filter

Check mark

Open the front panel

Check mark

Push a little upwards the filter tab at the center of each air filter, then pull it down

Check mark

Remove the titanium apatite photocatalytic air-purifying filter

Check mark

Choose the cleaning method

Check mark

Set the filters as they were and close the front panel

Check mark

Sign off on the air filter cleaning

Run this procedureArrow right

Parts for Daikin Air Conditioner FTXM25M2V1B

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Remote Controller

ARC466A33

Dry Battery

AAA.LR03

Remote Controller

ARC466A33

Dry Battery

AAA.LR03

Remote Controller

ARC466A33

Dry Battery

AAA.LR03

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets