Crown Battery 18-125VTA
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Battery Capacity Test
- A capacity test enables you to determine the capacity a battery actually delivers as compared to its rated capacity. This test can help determine if a battery should be repaired or replaced. When a battery delivers less than 80% of its rated capacity, the remaining capacity will decrease with each additional cycle
- It should be replaced before its cells fail and cause low-voltage operation of the vehicle, which can cause damage to the trucks electrical system
- A capacity test is performed by discharging a fully charged battery at a fixed rate (see chart on page 30) while monitoring specific test conditions, methods and procedures
- The six-hour rated discharge time is based on an electrolyte temperature of 77°F (25°C). Any deviation to that temperature, a correction to the six-hour rated time must be made
PROCEDURES FOR CAPACITY DISCHARGING:
1) Battery must be fully charged.
2) Specific gravities must be at manufacturers specifications, otherwise they must be adjusted accordingly.
3) Battery should be allowed to cool down prior to testing. Ideally, the temperature should be 75°F to 85°F. Otherwise the voltages will be affected by the temperature and the capacity must be temperature corrected.
4) Battery should be discharged within 24 hours of completion of charging and acid adjustment.
Battery Inspection
Warning: This inspection requires trained personnel with PPE!
Is the battery still in the vehicle?
If the battery is still in the vehicle, turn off the power switch and unplug the battery from the vehicle
Allow the battery to remain on open circuit (do not charge or discharge) for 30 minutes or longer
Fill in the Crown Battery Inspection Report. Include battery type, serial number, etc.
Read and record the specific gravity and open circuit voltage for all cells of the battery
Read and record the pilot cell temperature
Record the temperature-corrected specific gravity readings. Use a temperature correction thermometer. Use the pilot cell temperature for the temperature correction of all the cells.
It is not necessary to read the temperature of every cell unless the temperature difference between center cells and outside cells of the battery is 12°F or more
Battery Maintenance
- Properly charge battery
- Add water as needed
- Clean as required
Effective Battery Maintenance:
As is true with any piece of industrial equipment, proper maintenance not only keeps it operating to its design specifications, but also helps prolong the equipments life. The following effective battery maintenance tips can help achieve the best performance out of your industrial battery
1. Maintain the proper electrolyte level. Avoid overfilling
2. Charge properly, check charger controls and instruments periodically. Calibrate meters as needed
3. Repair any damage promptly. Minor damage, if not repaired in a timely manner, can lead to major damage
4. Don't overcharge, many batteries deliver short service life from too much charge
3 Monthly Battery Cleaning
- To prevent corrosion and the resultant problems, batteries must be cleaned and dries routinely
Sometimes minor spills or overflows of electrolyte occur due to overfilling. Instead of giving the battery a general cleaning at this time, the moisture can be removed with rags or paper towels. (This should be immediately disposed of.)
The frequency of a general cleaning depends upon two factors:
1. How quickly dust, dirt, oil, and other foreign matter accumulates on the top of the battery, and 2. How quick the electrolyte spillage accumulates
When the top of a battery is "dirty" or looks damp, it is ready for a general cleaning. It could be as often as every two weeks or as infrequent as every six months, depending on the battery's environment and the care it receives. The average battery needs general cleaning every three months
To give a battery a general cleaning, use Powerhouse Cleaner's 3 Step Process (Corrosion Remover, Battery Cleaner, Rinse)
Powerhouse's Corrosion Remover was developed specifically for the removal of heavy corrosion and acid neutralization. For use, spray onto the corroded areas (will turn a rust looking color) and let sit for at least 10 minutes
Powerhouse's Battery Cleaner is a mixture of 2 parts cleaning detergent to 1 part acid neutralizer. Battery Cleaner is OSHA compliant and environmentally safe. For use, spray across the entire battery and let sit for at least 10 minutes
After the Corrosion Remover and Battery Cleaner have both sat for at least 10 minutes the battery can now be rinsed. The corrosion and acid should be neutralized and can be washed down the drain (note if lead pieces from the top of the battery are in the water they should be disposed of properly.)
4 Yearly Battery Replacement
Warning: Battery replacement should be done by trained personnel only!
Old battery removed successfully?
New battery installed successfully?
Enter the voltage reading of the new battery
Sign off on the battery replacement
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX