The Bunn Coffee Machine 23001.0052 is a reliable commercial coffee brewing solution designed for high-volume environments. Known for its durability and efficiency, this model ensures consistent quality and flavor in every cup, making it a preferred choice for cafes and restaurants. Optimize your coffee service with Bunn's trusted technology.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Bunn Coffee Machine 23001.0052
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Coffee Machine Control Thermostat Replacement
Remove wires from control thermostat leads
Remove the thermostat capillary bulb by firmly pulling-up on the capillary at the tank lid
Remove the one #8-32 screw securing the control thermostat to the component bracket in the trunk
Slide the grommet to the line 4.5\ above the bulb on the new capillary tube"
Insert the capillary bulb through the hole in the tank lid and press the grommet firmly and evenly so that the groove in the grommet fits into the tank lid
Carefully bend the capillary tube so that the tube and bulb inside the tank are in the vertical position
NOTE - The capillary tube must be clear of any electrical termination and not kinked
Select the model of the machine
Early Models: Using two #8-32 screws secure the control thermostat inside the hood
Coffee Machine Control Thermostat Test
Warning: Disconnect the brewer from the power source before starting the test
Locate the blue wire on the control thermostat
Voltage across the blue wire on the control thermostat
Voltage is 120 volts ac for two wire 120 volt models and three wire 120/240 volt models or 200 to 230 volts ac for two wire 200 volt or 230 volt models
If voltage is not as described, refer to the wiring diagrams and check the brewer wiring harness
Locate the black wire on the control thermostat
Remove the capillary bulb and grommet from the tank
Voltage across the black wire of the control thermostat when the control thermostat is turned fully clockwise
Voltage is 120 volts ac for two wire 120 volt models and three wire 120/240 volt models or 200 to 230 volts ac for two wire 200 volt or 230 volt models
Coffee Machine Dial Timer Replacement
Warning: Disconnect the machine from power source before starting the procedure
Disconnect the timer socket from the brewer wiring harness and the timer leads from the solenoid valve
Remove the one #8-32 screw securing timer to component bracket
Install new timer on component bracket securing with one #8-32 screw
Upload a photo of the reconnected wires
Enter the timer dial adjustment
Sign off on the timer replacement
Coffee Machine Dial Timer Test
Warning: Disconnect the brewer from the power source before starting the procedure
Disconnect the polarized, three pin connector from the brewer wiring harness and rotate the brew timer dial fully counterclockwise
Check the voltage across sockets P2 & P3 (white and black wires) of the female connector when the 'ON/OFF' is in the 'ON' position
Voltage is 120 volts ac for two wire 120 volt models and three wire 120/240 volt models OR 200 to 230 volts ac on two wire 200 volt or 230 volt models
Check the voltage across the sockets P1 & P2 (blue and white wires) of the female connector when the 'ON/OFF' switch is in the 'ON' position and start switch pressed
Voltage is 120 volts ac for two wire 120 volt models and three wire 120/240 volt models OR 200 to 230 volts ac for two wire 200 volt or 230 volt models
Reconnect the three pin connector from main wiring harness to the timer
Disconnect the black and white wires from the solenoid
Check the voltage across the black and white wires when the 'ON/OFF' switch is in the 'ON' position and the 'START' switch is pressed to the 'START' position and released
Coffee Machine Digital Brew Timer Replacement
Remove the #8-32 screw securing circuit board to the mounting bracket
Remove circuit board and spacers (as required)
Remove all wires from the timer
Attach all wires to the replacement timer board prior to installation to the component mounting bracket. Refer to FIG. 21 when reconnecting the wires
Install new circuit board with spacers (as required) to the component mounting bracket
Adjust the timer as described below
Sign off on the timer replacement
Access the parts list for your equipment in MaintainX.
Thermostat
29329.1000
Thermostat
29329.1000
Thermostat
29329.1000
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX