The Airflow Systems Dust Collector DCH2-PG6 is a high-performance industrial dust collection solution designed to enhance air quality and operational efficiency. This model effectively captures airborne particulates, making it ideal for various manufacturing environments. Ensure optimal performance with regular maintenance and quality spare parts.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Airflow Systems Dust Collector DCH2-PG6
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Filter Cleaning
Ensure the Dust-Pak® dust collector is placed in the desired work area and no equipment will come into contact with the unit.
Is the hood approximately 10\ - 14\" from the source of smoke or dust?"
Switch the unit ON, allowing the contaminated air to be drawn into the collection unit.
Has the airflow volume decreased due to dirty filters?
Turn off the Dust-Pak® dust collector to initiate the Auto Clean Vibra-Pulse® filter cleaning system.
Adjust the control board if required to optimize cleaning.
Is the cleaning system initiated by loss of fan pressure?
Does the 'power on' LED light come on when the timer/power board is energized?
Do the individual output lights come on one at a time, in sequence?
6 Monthly Dust Cleaner Maintenance
Warning: This maintenance check requires trained personnel with PPE!
Motors in good condition
Blower wheels in good condition
Friction joints of arms in good condition
Pickup-hose in good condition
Gaskets in good condition
No dirt build-up on blower wheel and other rotating parts
Caster wheel bearings moving freely
Parts that need repair or replacement
After Filter Maintenance
Warning: Wear adequate personal protective devices during this operation. Airborne carbon dust is released.
Unhook latches and remove external filter end cap
Remove 2\ polyester afterfilter and discard"
Remove AD module and take to a well ventilated area
Remove cover plate and empty module contents into a plastic bag or other approved container
Refill with the new adsorber material. After initial refilling, shake module to pack granules tightly and top off any void in the module before replacing cover plate
Vacuum any excess carbon dust that occurs from settling during handling
Re-install both the AD module and new polyester afterfilter
Install external filter end cap and re-hook latches. Stay clear of the unit outlet area when unit is first turned on as some dust may be expelled
Filter Replacement
Confirm unit has completed any cleaning cycle
Follow lock-out/tag-out procedures preventing unit operation
Loosen knob in center of filter cover. Remove filter cover (Note: knob stays with cover)
There are two filters located behind the filter cover. If required, a plastic bag can be used to slide over each filter as they are removed from the filter housing. CAUTION: Dirty filters can be extremely heavy and awkward to handle. WEAR PERSONAL PROTECTIVE EQUIP- MENT AS REQUIRED
While the filter is out, inspect the Vibra-Pulse® hoses for cracks, splits or degrading. Conical end wear is normal. All hoses should be approximately 7\ long. Replace any hose that does not appear normal or which is worn to less than 6\""
Install new filters. *Small diameter gasket to be installed first (large diameter toward cap)
Inspect perimeter gasket on cabinet opening for damage and replace as necessary. Remove any debris accumulations
Locate and install filter cover assembly. Hand tighten securely, but do not over-tighten
Sign off on the filter replacement
Hose & Clamp Replacement
ENERGY-SOURCE WARNING: ALWAYS DISCONNECT THE UNIT FROM ALL ENERGY SOURCES BEFORE WORKING ON OR NEAR THE MOTOR OR WIRING ASSEMBLIES. LOCK OUT DISCONNECTS TO PREVENT UNEXPECTED APPLICATION OF POWER OR COMPRESSED AIR
Check for signs of excessive wear when doing normal filter service or if a decrease in filter cleaning effectiveness is observed
Turn unit off. Disconnect power and lock out
Disconnect air supply before working on unit and lock out
Remove filter access doors
Remove dust tray(s) and dispose of material in accordance with local, state, and federal
Remove cartridge filters) from unit
Remove the old Vibra Pulse® hose in one of two ways
Slide the double hose assembly onto the air cleaner’s hose barb until fully seated against brass hex on barb
Access the parts list for your equipment in MaintainX.
0-6" Pressure Gauge, Surface Mounted, Opt.
7NT3-1010
0-7" Dial Pressure Gauge, Flush Mounted, Opt.
7NT3-1001
1.5 HP Motor, 3 Phase, Opt.
7MP4-6301
1.5 HP Motor, Single Phase, Std.
7MP4-6101
2" Polyester Afterfilter (Used With AD), Opt.
2AF2-0011
0-6" Pressure Gauge, Surface Mounted, Opt.
7NT3-1010
0-7" Dial Pressure Gauge, Flush Mounted, Opt.
7NT3-1001
1.5 HP Motor, 3 Phase, Opt.
7MP4-6301
1.5 HP Motor, Single Phase, Std.
7MP4-6101
2" Polyester Afterfilter (Used With AD), Opt.
2AF2-0011
0-6" Pressure Gauge, Surface Mounted, Opt.
7NT3-1010
0-7" Dial Pressure Gauge, Flush Mounted, Opt.
7NT3-1001
1.5 HP Motor, 3 Phase, Opt.
7MP4-6301
1.5 HP Motor, Single Phase, Std.
7MP4-6101
2" Polyester Afterfilter (Used With AD), Opt.
2AF2-0011
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX