Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

AERCO International Boiler Benchmark 1500
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
12 Monthly Air Filter Maintenance
Warning: This maintenance check requires trained personnel with PPE!
Is the boiler operational?
If boiler is not operational, report the issues to the maintenance team and stop the procedure
Switch off the boiler and disconnect AC power from the unit.
Remove the top shroud from the unit by grasping the top handle and lifting straight up.
Locate the air filter attached to the air/fuel valve inlet.
Using a flat-tip screwdriver or 5/16” nut driver, loosen the clamp securing the filter to the inlet flange of the air/fuel valve. Remove the filter and clamp.
Clean the filter in hot soapy water to remove oil and dirt. Dry the filter and then spray with a light coating of oil, such as WD-40, prior to reinstallation.
Install the replacement air filter on inlet flange of the air fuel valve and tighten the clamp with a flat-tip screwdriver or 5/16” nut driver.
12 Monthly Condensate Drain Trap Maintenance
Warning: To avoid personal injury, ensure that the following guidelines are strictly observed before servicing: Disconnect the AC supply by turning off the service switch and AC supply circuit breaker. Shut off the gas supply at the manual shut-off valve provided with the unit. Allow the unit to cool to a safe water temperature to prevent burning or scalding.
Replace Condensate Drain Trap
Cleaning Condensate Drain Trap
Disconnect the external condensate trap by loosening the union pipe connection between the trap and the exhaust manifold drain pipe.
Remove the connections on the inlet and outlet sides of the condensate trap.
Loosen the four (4) thumbscrews securing the cover on the condensate trap. Remove the cover.
Remove the float from the condensate trap.
Remove the O-ring and orifice gaskets from the trap. These items should be replaced annually.
Thoroughly clean the trap and float. Also inspect the drain piping for blockage. If the trap cannot be thoroughly cleaned, replace the trap.
1 Daily Boiler Test
WARNING: Periodic testing of all boiler controls and safety devices is required to determine that they are operating as designed. Precautions shall be taken while tests are being performed to protect against bodily injury and property damage. The owner or user of an automatic boiler system should set up a formal system of periodic preventive maintenance and testing. Tests should be conducted on a regular basis and the results recorded in a log-book.
Gauges, monitors and indicators: Visual inspection and record readings in operator log
Instrument and equipment settings: Visual check against factory recommended specifications
Sign off on the daily boiler test
1 Monthly Boiler Test
WARNING: Periodic testing of all boiler controls and safety devices is required to determine that they are operating as designed. Precautions shall be taken while tests are being performed to protect against bodily injury and property damage.
The owner or user of an automatic boiler system should set up a formal system of periodic preventive maintenance and testing. Tests should be conducted on a regular basis and the results recorded in a log-book.
Flue, vent, stack or intake air duct: Visually inspection condition and check for obstructions
Low air flow: See section 6.8
Disable the blower output drive voltage
Start the unit in the Manual Mode at a valve position between 25% and 30%.
The unit should shut down and lockout, showing AIRFLOW FAULT DURING PURGE in the display.
The unit should perform one IGNITION RETRY cycle and then shut down, since the blower is disabled. The unit will then display AIRFLOW FAULT DURING PURGE.
Re-enable the blower output drive voltage
1 Weekly Boiler Test
WARNING: Periodic testing of all boiler controls and safety devices is required to determine that they are operating as designed. Precautions shall be taken while tests are being performed to protect against bodily injury and property damage. The owner or user of an automatic boiler system should set up a formal system of periodic preventive maintenance and testing. Tests should be conducted on a regular basis and the results recorded in a log-book.
Instrument and equipment settings: Verify factory settings
Spark Igniter-Injector:
1. Set the ON/OFF switch on the control panel, to the OFF position. Disconnect AC power from the unit
2. Remove the top shroud from the unit by grasping the top handle and lifting straight up. This will disengage the shroud from the four (4) pins in the side panels.
3. Disconnect the cable from the igniter-injector (Figure 7-1).
4. Refer to the partial exploded view in Figure 7-2. Using a 7/16” open-end wrench, disconnect the compression nut securing the gas injector tube of the igniter-injector to the elbow of the staged ignition assembly. Disconnect the staged ignition assembly from the igniter-injector.
5. Next, loosen and remove the igniter-injector from the burner plate using a 1" open-end wrench.
6. Check the igniter-injector for evidence of erosion or carbon build-up. If there is evidence of substantial erosion or carbon build-up, the igniter-injector should be replaced. If carbon build-up is present, clean the component using fine emery cloth. Repeated carbon buildup is an indication that the combustion settings of the unit should be checked. Refer to Chapter 4 for combustion calibration procedures.
Access the parts list for your equipment in MaintainX.
100 Psi Kit (Conbraco)
58088-C100
100 Psi Kit (Watts)
58088-W100
125 Psi Kit (Conbraco)
58088-C125
125 Psi Kit (Watts)
58088-W125
12V Power Suply
65109
100 Psi Kit (Conbraco)
58088-C100
100 Psi Kit (Watts)
58088-W100
125 Psi Kit (Conbraco)
58088-C125
125 Psi Kit (Watts)
58088-W125
12V Power Suply
65109
100 Psi Kit (Conbraco)
58088-C100
100 Psi Kit (Watts)
58088-W100
125 Psi Kit (Conbraco)
58088-C125
125 Psi Kit (Watts)
58088-W125
12V Power Suply
65109
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX