MaintainX Logo
EnterprisePricing
ABB

ABB ABB Enclosed Variable Speed/Frequency Drive ACS880-07-0650A-7 ACS880-07-0650A-7

Need answers fast?
Explore the manual using AI.

ABB ABB Enclosed Variable Speed/Frequency Drive ACS880-07-0650A-7 ACS880-07-0650A-7
ABB ABB Enclosed Variable Speed/Frequency Drive ACS880-07-0650A-7 ACS880-07-0650A-7

The ABB Enclosed Variable Speed/Frequency Drive ACS880-07-0650A-7 is designed for efficient motor control and energy savings in industrial applications. This advanced drive offers flexible integration and robust performance, making it ideal for various automation needs.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for ABB ABB Enclosed Variable Speed/Frequency Drive ACS880-07-0650A-7 ACS880-07-0650A-7

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

ABB ABB Enclosed Variable Speed/Frequency Drive ACS880-07-0650A-7 ACS880-07-0650A-7

ABB ABB Enclosed Variable Speed/Frequency Drive ACS880-07-0650A-7 ACS880-07-0650A-7

Create an account to install this asset package.

Maintenance Plans for ABB ABB Enclosed Variable Speed/Frequency Drive ACS880-07-0650A-7 Model ACS880-07-0650A-7

Integrate maintenance plans directly into your work orders in MaintainX.

9 Yearly Circuit Board Compartment Cooling Fan Replacement

Check mark

WARNING! Obey the safety instructions of the drive. If you ignore them, injury or death, or damage to the equipment can occur. If you are not a qualified electrical professional, do not do installation, commissioning or maintenance work.

Check mark

Drive stopped and electrical safety precautions followed

Check mark

Drive module removed from the cabinet

Check mark

Fastening screw of the fan enclosure undone

Check mark

Power supply cable of the fan unplugged

Check mark

New fan installed in reverse order

Check mark

Counter reset in group 5 in the primary control program

Check mark

Sign off on the fan replacement

Run this procedureArrow right

1 Yearly Drive Maintenance

Check mark

Performance quality of supply voltage

Check mark

Inspect spare parts

Check mark

Performance DC circuit capacitors reforming, spare modules and spare capacitors

Check mark

Inspect IP22 and IP42 air inlet and outlet meshes

Check mark

Inspect tightness of terminals

Check mark

Inspect dustiness, corrosion and temperature

Check mark

ABB-SACE Air circuit breaker maintenance

Check mark

Sign off on the 1 Yearly Drive Maintenance

Run this procedureArrow right

6 Yearly ZCU-12 Control Unit Battery Replacement

Check mark

Warning: For trained personnel only

Check mark

Drive stopped and electrical safety precautions taken

Check mark

Battery ejector moved into the battery slot on the battery

Check mark

Old battery carefully pulled out of the battery holder

Check mark

New CR2032 battery carefully put into the battery holder

Check mark

Sign off on the battery replacement

Run this procedureArrow right

6 Yearly IP54 (UL type 12) Roof Fan 60 Hz Replacement

Check mark

WARNING! Obey the safety instructions of the drive. If you ignore them, injury or death, or damage to the equipment can occur. If you are not a qualified electrical professional, do not do installation, commissioning or maintenance work.

Check mark

Drive stopped and electrical safety precautions followed

Check mark

Front and back gratings slid upwards and removed

Check mark

Mounting screws of the upper cover removed and cover lifted off

Check mark

Fan power supply wires disconnected

Check mark

Mounting screws of the fan removed

Check mark

Mounting screws of the fan cover removed

Check mark

Fan lifted off

Check mark

New fan installed in reverse order

Run this procedureArrow right

ZCU-14 Memory Unit Replacement

Check mark

WARNING! Do not remove or insert the memory unit when the control unit is powered.

Check mark

WARNING! Obey the safety instructions of the drive. If you ignore them, injury or death, or damage to the equipment can occur. If you are not a qualified electrical professional, do not do installation, commissioning or maintenance work.

Check mark

Drive stopped and electrical safety precautions followed

Check mark

Clip of the memory unit pulled forward

Check mark

Memory unit taken off

Check mark

Memory unit replaced in reverse order

Check mark

Sign off on the memory unit replacement

Run this procedureArrow right

Parts for ABB ABB Enclosed Variable Speed/Frequency Drive ACS880-07-0650A-7 ACS880-07-0650A-7

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Fuse IEC

SC33AR69V10CTF

Sine Filter

NSIN0900-6

Fuse UL

170M6414

Fuse IEC

170M6414

Fuse IEC

SC33AR69V10CTF

Sine Filter

NSIN0900-6

Fuse UL

170M6414

Fuse IEC

170M6414

Fuse IEC

SC33AR69V10CTF

Sine Filter

NSIN0900-6

Fuse UL

170M6414

Fuse IEC

170M6414

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from ABB

Explore Other Assets