Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Twin Disc Marine Transmission MGX-5126A
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1000 Hourly / 6 Monthly New Transmission Filter and Oil Change
Change oil and filter element after each 1000 hours of operation, or six months, whichever comes first. Change the oil more frequently if conditions warrant.
F. Suction Strainer
Remove and clean the suction strainer at every oil change or sooner if necessary. See illustrations in Section 6.2 for the location of the suction strainer for your transmission.
Draining
Drain the transmission by removing the oil drain plug from the rear/bottom of the transmission. See the illustrations in Section 6.2 or service literature for your transmission for location of transmission and filter drain plugs.
NOTE: Dispose of used oil and oil filters in accordance with federal, state or local laws. Exercise precautions to prevent environmental contamination during any transmission servicing procedure.
Filling
1. Remove the breather or the oil fill closure from the top of transmission case.
2. Pour new oil through breather or closure opening. Fill with recommended clean oil, taking necessary precautions to prevent entry of dirt or debris. (See lubrication plate on transmission and information transcribed to the front of this manual for additional oil information.);
1000 Hourly Rebuilt Transmission Filter and Oil Change
Look for lint or other material that may collect from rags or towels used in the parts cleaning process.
Look for chips or shavings particularly if the transmission has had a problem that caused debris in the system. (For units with spin-on filters, this will require cutting the filter element apart to access the element core.); If the filter is clean, install a new filter element and then change the oil and filter element after 1000 hours of service. If the filter is dirty, change the element and operate for another eight hours. Check the filter again.
Continue this cycle until the filter is clean and then change the oil and filter after 1000 hours of service, or more often if conditions warrant.
NOTE: Situations involving debris in the hydraulic system will require that heat exchangers and all connecting lines and hoses be thoroughly cleaned. If the heat exchanger cannot be disassembled, or if it cannot be assured that all debris is removed, the heat exchanger should be replaced.
F. Suction Strainer
Remove and clean the suction strainer at every oil change or sooner if necessary. See illustrations in Section 6.2 for the location of the suction strainer for your transmission.
Draining
Drain the transmission by removing the oil drain plug from the rear/bottom of the transmission. See the illustrations in Section 6.2 or service literature for your transmission for location of transmission and filter drain plugs.
NOTE: Dispose of used oil and oil filters in accordance with federal, state or local laws. Exercise precautions to prevent environmental contamination during any transmission servicing procedure.
100 Hourly Safety Valve Lubrication
Lubrication
If your unit is equipped with a lubrication fitting, grease the oil seals at the output end of the transmission output shaft through the lubrication fitting with water pump grease.
See the illustrations in Section 6.2 for location of the lubrication fitting.
Apply grease approximately every 100 hours when boat is docked.
No other lubrication is required.
NOTE: Preferred grease is one with lithium soap, NLGI consistency #2 for component temperatures above 20° C (68° F).
Did you apply the grease as instructed?
Sign off on the lubrication process
10 Hourly / 1 Daily Oil Level Check
Oil Level Check
Engine running at low idle and marine transmission in neutral
Transmission oil temperature
Startup
Transmission control in NEUTRAL
Transmission oil pressure
Pressure registered within 15 seconds
Check the oil level
Transmission filled to LOW mark on the dipstick
2000 Hourly / 6 Monthly Flexible Input Coupling Inspection
Warning: Do not obstruct the flywheel housing vents
Free flow of air for cooling the coupling
Operating air temperature
Operating air temperatures above -6°C (22°F) and below 82°C (180°F) must be maintained
Visual inspection of the coupling after the first 100 hours of operation
Visual inspection of the coupling every 2000 hours thereafter, or every six months, whichever comes first
Check for torsional vibration
Check for misalignment
Check for degradation by contaminants (oil)
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX