Thermo Fisher Radiation Monitor RM-20
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
True Frequency Calibration
Initial Setup
Ensure necessary equipment is available
Connect the pulser to the instrument through the capacitor
RM-20 DISCR Control Setup
Set the RM-20 DISCR control for 1 V between pins 10 and 11 of A103
Set the ALARM SET control fully clockwise
Set the GM/P switch to P
Pulse Generator Connection and Calibration
Connect the pulser to the DETECTOR connector on the front panel
Detector Response Calibration
Detector Setup
Set the GM/P switch
Adjust DISCR control to simulate increased gain, ensuring sensitivity is above internal noise level
Voltage Adjustment
Is the proper high voltage known?
Set controls to the known proper voltage
Set voltage low and connect the detector
Plot voltage plateau curve
Set high voltage to the best operating value
High Voltage Indication Calibration
Preparation
Ensure the following equipment is available
Connection Setup
Connect the positive side of the high voltage voltmeter to the outboard end of C117, the high voltage filter capacitor.
Connect the reference side to chassis ground at the lug on the DETECTOR connector.
Set the range switch to the HV position.
Calibration Adjustment
Adjust the HV ADJ potentiometer R149 until the high voltage meter reads 2000 V.
Adjust the HV CAL potentiometer R147 until the front panel meter indicates 2.0 kV.
Radiation Monitor Disassembly
Cover Removal
Remove the 10-32 screw from each side of the unit
Lift the cover off
Circuit Board Removal
Unplug connectors
Remove knobs and nuts from board-mounted components
Unscrew the AC input connector and line filter assembly from the rear panel
Remove the two 4-40 screws at the rear corners of the board
Is the battery installed?
Access the parts list for your equipment in MaintainX.
Power Cord 3-Wire, #18
WRAC4 (4)
Speaker
ADSP3 (6)
Lamp 14 V, 0.08 A
LPBU6 (5)
Fuse 3 Ag, 1/8 A, Slo Blo
FUSB2 (1)
Fuse 3 Ag, 1 A, Slo Blo
FUSB12 (1)
Power Cord 3-Wire, #18
WRAC4 (4)
Speaker
ADSP3 (6)
Lamp 14 V, 0.08 A
LPBU6 (5)
Fuse 3 Ag, 1/8 A, Slo Blo
FUSB2 (1)
Fuse 3 Ag, 1 A, Slo Blo
FUSB12 (1)
Power Cord 3-Wire, #18
WRAC4 (4)
Speaker
ADSP3 (6)
Lamp 14 V, 0.08 A
LPBU6 (5)
Fuse 3 Ag, 1/8 A, Slo Blo
FUSB2 (1)
Fuse 3 Ag, 1 A, Slo Blo
FUSB12 (1)
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX