MaintainX Asset Hub logo
EnterprisePricing
Stryker

Stryker Stretcher 6516 POWER PRO IT

Need answers fast?
Explore the manual using AI.

Stryker Stretcher 6516 POWER PRO IT
Stryker Stretcher 6516 POWER PRO IT

The Stryker Stretcher 6516 POWER PRO IT is a high-performance medical transport solution designed for patient safety and comfort. This stretcher features advanced power capabilities, ensuring efficient mobility and ease of use in emergency situations, making it an essential asset for healthcare providers.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Stryker Stretcher 6516 POWER PRO IT

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Stryker Stretcher 6516 POWER PRO IT

Stryker Stretcher 6516 POWER PRO IT

Create an account to install this asset package.

Maintenance Plans for Stryker Stretcher Model 6516 POWER PRO IT

Integrate maintenance plans directly into your work orders in MaintainX.

12 Hourly / 6 Monthly Maintenance

Check mark

Inspect hoses and fittings for damage or wear

Check mark

Verify the hydraulic velocity fuse

Check mark

Measure and check load height

Check mark

Verify 'jog' function is operating

Check mark

Verify high speed retract is working

Check mark

Verify there is no damage or wear to either switch

Check mark

Verify both switches operate correctly

Check mark

Verify no bent, broken or damaged components

Check mark

Verify no damage or tears on cot grips

Run this procedureArrow right

24 Hourly / 12 Monthly Maintenance

Check mark

Cot and fastener fit and function properly

Check mark

Safety bar engages the vehicle safety hook properly

Check mark

Cylinder is adjusted so the lock nut is tight and the cot stops moving when it hits the dead stops

Check mark

Manual back-up release handle returns to the stowed position

Check mark

All welds intact, not cracked or broken

Check mark

Warning labels present, legible (reference assembly drawings)

Check mark

All welds intact, not cracked or broken

Check mark

Optional wheel lock(s) checked and adjusted as necessary

Check mark

Sign off on the maintenance check

Run this procedureArrow right

2 Hourly / Monthly Maintenance

Check mark

In-fastener shut-off configured properly

Check mark

Cylinder rod extended and wiped down with soft cloth and household cleaner

Check mark

Routing(s) and connection(s) checked, no hanging wires

Check mark

Manual back-up release handle functions properly

Check mark

Cot frame/litter inspected

Check mark

Cot frame/base inspected

Check mark

All wheels secure, rolling and swiveling properly

Check mark

Safety bar operates properly. Pull toward the head section to ensure that it swings and rotates freely and pulls back to home position.

Check mark

SMRT Pak housing and terminal area inspected for cracks or damage

Run this procedureArrow right

6 Hourly / 3 Monthly Maintenance

Check mark

All fasteners are secure

Check mark

No hydraulic fluid (red) leaks

Check mark

Motor mount fasteners are secure

Check mark

No hydraulic fluid leaks

Check mark

No leaks in the reservoir

Check mark

No damage or pinching of wiring hamness, cables or lines

Check mark

No damaged connectors

Check mark

Base extends/retracts smoothly when the manual back-up release handle is engaged

Check mark

With 100 Ib or more on the cot, the cot does not lower when the manual backup release handle is pulled

Run this procedureArrow right

Cot Retaining Post Screw Replacement

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

Using a T25 Torx driver or 5/32” hex wrench, remove the button head cap screw that secures the retaining post cap and post tube to the top pin bracket. Discard the screw.

Check mark

Using a 5/32” hex wrench, install and tighten the button head cap screw (p/n 0004-503-000) completely to secure the retaining post cap and tube to the top portion of the retaining post assembly. Using a torque wrench, torque the screw to 100-140 in-lb.

Check mark

Verify proper operation of the unit before returning it to service.

Check mark

Sign off on the cot retaining post screw replacement

Run this procedureArrow right

Parts for Stryker Stretcher 6516 POWER PRO IT

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Base Assembly

6506-001-012

Base Dead Stop

6500-001-125

Base Strap Clamp

6500-001-310

Base Strap, Left

6500-001-309

Base Strap, Right

6500-001-308

Base Assembly

6506-001-012

Base Dead Stop

6500-001-125

Base Strap Clamp

6500-001-310

Base Strap, Left

6500-001-309

Base Strap, Right

6500-001-308

Base Assembly

6506-001-012

Base Dead Stop

6500-001-125

Base Strap Clamp

6500-001-310

Base Strap, Left

6500-001-309

Base Strap, Right

6500-001-308

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Stryker

Explore Other Assets