The Schneider Electric Compressor SEM 100-8-6 W-oilfree is a high-performance, oil-free compressor designed for efficient operation in various industrial applications. With its robust construction and advanced features, this model ensures reliable air supply while minimizing maintenance needs and operational costs.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Schneider Electric Compressor SEM 100-8-6 W-oilfree
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
10 Yearly Pressure Test
Special inspections are not required for this compressor.
We recommend that a "qualified person" perform a pressure test on the vessel after 10 years, depending on general levels of wear and tear.
A "qualified person" should be well informed about Ordinance on Industrial Safety and Health (formerly authorised expert)
Contact any of our approved service partners. Most of our service partners have employees with expert qualifications.
2500 Hourly Replacement
- Change safety valve:
1. Detach the safety valve (item 11) by unscrewing it anticlockwise.
2. Screw the new safety valve into place by screwing it clockwise.
500 Hourly Maintenance
- Change intake filter:
1. Remove the filter insert cover.
2. Pull out the filter insert. (Fig. 5a)
3. Clean the filter insert using the blow gun, exchange the filter insert if necessary.
4. Insert the filter insert, push the cover shut.
Do not purge the intake opening. No foreign objects may enter.
Never operate the compressor without an intake filter.
- Change check valve and insert:
1. Unscrew the locking screw (Figure 6a).
50 Hourly Maintenance
- Cleaning the intake filter:
1. Remove the filter insert cover.
2. Pull out the filter insert. (Fig. 5a)
3. Clean the filter insert using the blow gun, exchange the filter insert if necessary.
4. Insert the filter insert, push the cover shut.
Do not purge the intake opening. No foreign objects may enter.
Never operate the compressor without an intake filter.
Initial 10 Hours Check
- Check screw connections once after 10 hours.
1. Check all screw connections for tight fit and retighten if necessary.
2. Observe the tightening torques (tightening torques calculated according to VDI 2230).
Access the parts list for your equipment in MaintainX.
Check valve
-
Compressor unit
-
Condensate drain valve
-
Electric motor
-
External protective motor switch
-
Check valve
-
Compressor unit
-
Condensate drain valve
-
Electric motor
-
External protective motor switch
-
Check valve
-
Compressor unit
-
Condensate drain valve
-
Electric motor
-
External protective motor switch
-
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX